The mounting plate may be used to mount over flush or surface mounted 

electrical boxes or mud rings and fits securely to a 2 gang electrical box for 
installation with wiring conduit.  

 

The 8128 Strobe is rated IP65 for wet locations however care must be 

taken to ensure that water does not enter the wiring cavity. The supplied 

gaskets or sealant must be used to protect the wiring cavity in wet 
environments. In dry indoor environments the gaskets are not required. If 

the wall gasket is used with surface wiring then the gasket should be 
attached after placing the cable into the wiring channel. 

 

The 8128 Strobe should not be installed beyond a building perimeter 
without adequately protecting the building wiring from lightning surge.   

 

 

 

 
What's Included 

 

 

8128 Strobe unit with clear lens 

 

Mounting bracket 

 

Gaskets 

 

Colored lens cover (if color option ordered) 

 

This guide 

 

Summary of Contents for 8128

Page 1: ...Canada V5J 5L2 support algosolutions com Page 1 www algosolutions com 8128 SIP LED Strobe Light FW Version 2 3 Installation Configuration 8128 Clear lens only 8128A Clear lens with AMBER cover 8128B C...

Page 2: ...10 Authentication Password 10 Monitoring Mode 11 Activating 8128 Strobe Using Subscribe Notify 11 Basic Settings Tab Features 12 Flash Patterns 12 Flash Pattern Test 13 Cadence 14 Relay Input Detecti...

Page 3: ...anced Settings Administration 23 Password 23 Confirmation 24 Device Name 24 NTP Time Server 24 Introduction Section on Status Page 24 Log Level 24 Log Size 24 Log Method 24 Log Server 24 Hardware Watc...

Page 4: ...HOTO SENSITIVITY in some people with epilepsy can trigger seizures from flashing or flickering lights It is possible that some flash patterns of the 8128 Strobe could trigger a seizure for some indivi...

Page 5: ...al pattern is chosen The 8128 Strobe can be activated by SIP Ring SIP Message Waiting SIP In Use Subscribe Notify Dry contact closure input Multicasting If multiple 8128 Strobes are required the multi...

Page 6: ...www algosolutions com locator 4 Access the 8128 Strobe web page by entering the IP address into a browser and login using algo as the default password 5 Enter the IP address for the SIP server into th...

Page 7: ...ust be taken to ensure that water does not enter the wiring cavity The supplied gaskets or sealant must be used to protect the wiring cavity in wet environments In dry indoor environments the gaskets...

Page 8: ...power injector Terminal Block Relay In By default shorting these terminals will cause the 8128 Strobe to activate Terminal Block Relay Out By default these terminals provide a contact closure when the...

Page 9: ...02 20 4500 Beedie St Burnaby BC Canada V5J 5L2 support algosolutions com Page 9 www algosolutions com Web Interface Login The web interface requires a password which is algo by default This password...

Page 10: ...s are made to settings in the web interface the Save key must be clicked to save the changes SIP Domain Proxy Server SIP Server Name or IP Address SIP Extension This is the SIP extension for the 8128...

Page 11: ...P Ring Event Set Monitoring Mode to Monitor Ring When a call is made to the SIP extension the 8128 Strobe will flash Often the 8128 Strobe will be part of a hunt group or ring group to flash in conjun...

Page 12: ...IP servers varies by vendor and release As of FW Version 2 3 only ring and in use are enabled however it may also be possible to detect events such as message waiting or ACD queue status Please contac...

Page 13: ...ble PHOTO SENSITIVITY in some people with epilepsy can trigger seizures from flashing or flickering lights It is possible that some flash patterns of the 8128 Strobe could trigger a seizure for some i...

Page 14: ...door contact it can be made to flash only while the door is open input active Or the door open event can trigger the 8128 Strobe which will remain active even after the door is closed The 8128 Strobe...

Page 15: ...gurable multicast zone and all the slave units listen to the multicast zones assigned to them When a master unit receives a valid SIP ring event it will flash locally and also send out a special packe...

Page 16: ...c Settings Tab Multicast Master Settings Multicast Mode Master Selected If master is enabled the 8128 Strobe will broadcast an IP stream when activated in addition to flashing This option is available...

Page 17: ...8128 Strobe to activate Algo 8180 Audio Alerters via multicast www algosolutions com 8180 Zone Definitions Multicast IP addresses and ports are configured by default These typically do not need to be...

Page 18: ...ulticast Mode Slave Selected If slave is enabled the 8128 Strobe will activate when receiving a multicast message Depending on the settings of the Master the 8128 Strobe will mimic the master flash pa...

Page 19: ...support algosolutions com Page 19 www algosolutions com Zone Definitions See information in previous section under Master settings Advanced Settings SIP Outbound Proxy IP address for outbound proxy A...

Page 20: ...ecessary The configuration allows re registration to the primary server upon availability or to stay with a server until unresponsive Backup Server 1 If primary server is unreachable the 8128 Strobe w...

Page 21: ...Burnaby BC Canada V5J 5L2 support algosolutions com Page 21 www algosolutions com Automatic Failback Reconnect with higher priority server once available even if backup connection still fine Polling M...

Page 22: ...p and defines the Generic Attribute Registration Protocol VLAN ID Specifies the VLAN to which the Ethernet frame belongs A 12 bit field specifying the VLAN to which the Ethernet frame belongs The hexa...

Page 23: ...assuming the server is not available After such time the 8128 Strobe will use its default address of 192 168 1 111 Default time is 60 seconds Advanced Settings Administration Password Password to log...

Page 24: ...on text to be hidden from the login screen Log Level Use on the advice of Algo technical support only Log Size Consult Algo technical support Log Method Allows the 8128 Strobe to write to external Sys...

Page 25: ...sure consistent setups There are two different Provisioning methods that can be used via DHCP Option 66 or via a Static Server In addition there are three different ways to download provisioning files...

Page 26: ...5 The application doesn t need an installation To use the tool simply unzip and run the application md5 from a command prompt The proper md5 file will be generated in the same directory If using the a...

Page 27: ...tings txt to algom MAC address conf e g algom0022EE020009 conf 3 File algom MAC address conf can now be uploaded on the Provisioning server The specific configuration file will only be downloaded by t...

Page 28: ...ings to factory default values Reboot the Device Reboots the device Firmware Image Point to the firmware image provided by Algo MD5 Checksum Point to the checksum file provided by Algo Upgrade 8128 St...

Page 29: ...the upgrade is complete confirm that the firmware version has changed refer to top right of Control Panel System Network Logging Use on the advice of Algo technical support only Optional Colored Lens...

Page 30: ...198 Cd Strobe Triggers SIP extension ring Subscribe Notify multicast dry contact input Relay Output Max 30 V 50 mA Relay Input Max 1 kOhm Flash Patterns 16 Selectable patterns Programming Web interfa...

Page 31: ...and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this...

Page 32: ...Document 90 00066 Algo Communication Products Ltd 604 454 3792 2014 02 20 4500 Beedie St Burnaby BC Canada V5J 5L2 support algosolutions com Page 32 www algosolutions com...

Reviews: