www.algosolutions.com
PoE and Relay Connections on back of 8061 IP Relay Controller:
1.
Connect the 8061 to the network via an Ethernet cable at the back
of the device. Ensure that a PoE port is used for power and that the
8061 is connected to the same subnet and VLAN as the target
intercom.
2.
Run two wires from the door strike to the Normally Open/Common
(NO/C) input pair or Common/Normally Closer (C/NC) input pair on
the 8061. For more wiring information please visit:
www.algosolutions.com/doorstrike
.
Configuring the 8061
1.
Find the IP address of the Algo 8061 using the Algo locator tool
available from the Algo website
www.algosolutions.com/locator
). This
tool displays all of the Algo devices available on the network, and
their corresponding IP addresses. Note this address down as you will
need it when you configure the 8036 for use with this device.
2.
Point your browser to the above IP address. The 8061 Control Panel
will be displayed.
3.
Log in. The default password is algo.
4.
Go to the Basic Settings > Door Control tab.