5.5. Data Transmission Direct:
Adjustment:
Code-switch (12) from TED-TX and TED-RX on position 6.
Adapter 119--1 must be connected to TED-TX (short-cut between pin 2 and 3 at
DIN socket (7)).
Each data string must be sent with 2400 or 4800 Baud. You do not need any control characters.
The transmitter (TED-TX) is always on, this means a net device (NLG8) is recommended.
Data will not be checked by the receiver (TED-RX), but as they are received forwarded to the
plugged device. The device that receives the data should check the data (e.g. PC).
Advantage:
Each data string will be sent, you must not keep a certain format. You do not need
control characters.
Disadvantage: The TED-TX has a high power consumption, since it is always on. Since the data
are not sent with a protocol it is not possible to check them at the TED-RX.
Operation:
Wireless data transmission without data protocol from one device to another
(e.g. PC to PC).
ALGE TdC 8000 transmits data to a PC through the RS 232 interface
PC transmits data to another PC
Attention:
You must use adapter 119--1 in this mode!