www.alfrescoheaters.ie
7
3.
I
NSTALLATION
I
NSTRUCTIONS
Warning!
The heater must only be installed by a qualified electrician. Never attempt to carry out an
installation while the electrical power is switched on.
Please remove all protective plastic from the heater before installation!
3.1.
Items Required
You can refer to the following table for information on what items are supplied with the installation pack
and what additional items you may require.
Qty. Items Supplied
Qty. Tools & Additional Items Required (Not Supplied)
1
Radiant heater
4
Mounting fasteners
(appropriate for surface, 25 x 5mm)
1-2
Quartz elements
1
Phillips screwdriver
2
Mounting brackets
Drilling and electrical installation equipment
2
Spanners
Ensure that all the items listed under the
Items Supplied
column are included in your installation pack. If
not, please contact your supplier.
3.2.
Installation Clearance
Clearance distances vary between different models. You can check the appropriate clearance distances for
your model in the following table.
Model
ALF 20
ALF 30
ALF 40
ALF 50
ALF 60
ALF 80
Mounting Height
1.9 - 2.4m
2.1 - 2.5m
2.1 - 2.5m
2.1 - 2.5m
2.5 - 3m
2.5 - 3.5m
Distance from
Mounting Surface
15cm
15cm
15cm
15cm
15cm
15cm
3.3.
Mounting the Heater
Warning!
Do not mount the heater vertically. It must always be mounted horizontally.
Alfresco heaters are suitable for both wall and ceiling mounting. Ensure that you refer to the installation
precautions under
Important Safety Instructions
before starting to mount the heater.
1.
Mark the mounting hole centres on the ceiling or wall in accordance with the measurements in the
following diagrams.
Mounting distances for
models
ALF 30, 40, 60, 80
16.0cm
156.5cm between mounting hole centres