background image

HOW TO USE

To Enable Privacy Mode (Inside Deadlock), Push and HOLD the Multi-function button on Back Assembly 
for 3 Seconds. 
When Privacy mode is enabled, it restricts ALL accesses, including Master Pin Code, User PIN Code, Access 
Card and Digital Bluetooth Keys sent through APP. 
This feature will be disabled automatically after unlock the device with the lever handle from the inside or 
override key from the outside.

Enable Privacy Mode

3

secs

Use Visual PIN Protection

User can prevent PIN code exposure from strangers by entering additional random digits before 
or after their User Pin Code to unlock their device. In both cases the User Pin code is still intact 
but to a stranger it cannot easily be guessed.

Use Emergency USB-C Power Port and Reboot Button

USB-C Power Port

Reboot Button

Power bank(USB-C)
Not included in package

In the scenario where the Locks batteries are completely warn out and the lock will no longer turn on, you can connect any standard 
USB-C power banks to the Emergency Power port located on both side of the Touch screen Keypad. Connect with a USB-C cable to 
power lock to unlock latch bolt to get inside so you can charge your rechargeable battery.

In the scenario where the lock freezes or becomes unresponsive, the lock can be restarted by pressing the reboot button located 
on both side of the touch screen lock next to the Emergency USB-C Power port. This will keep all lock settings in place but will 
restart the lock. 

USB-C Power Port

Reboot Button

14/15

Summary of Contents for ML2

Page 1: ...ming Instructions Alfred International Inc reserves all rights for the final interpretation of the following instructions All design and specifications are subject to change without notice EN VER 1 0 Smart Door Lock ...

Page 2: ...Alfred Home Search Alfred Home in either the Apple App Store or Google Play to Download ...

Page 3: ...terference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly approved by the party respon...

Page 4: ...etween 1 250 it will be assigned automatically then read by voice guide after enrollment 3 User Pin Codes Can be 4 10 digits and can be set up through Master Mode or Alfred Home App 4 Access Card Number slots Access card can be assigned number slots between 1 250 it will be assigned automatically then read by voice guide after enrollment 5 Access Card Only Mifare 1 type card is supported for ML2 I...

Page 5: ...sembly A B C D E F G H I J A Status indicator Red B Status indicator Green C Touchscreen keypad D Low battery indicator E Wireless module port F Handing switch G Reset button H Internal indicator I Multi functional button J Thumb turn 3 15 ...

Page 6: ...g thumb turn from inside or pressing multiple function button on interior assembly from inside Centered Control Platform The lock can be integrated with Centered Control Platform by using a wireless module Sold separately the ML2 support Z wave and Zigbee modules More information please refer to instruction of optional wireless module Auto Re lock After lock has been successfully unlocked it will ...

Page 7: ...age settings on the Alfred Home App Keypad Lockout The lock will go into KeyPad Lockout for a default of 5 mins after the wrong code entry limit has been met 10 attempts Once the unit has been placed in shutdown mode due to the limit being reached the screen will flash and will prevent any keypad digits from being entered until the 5 min time limit has expired The Wrong code entry limit resets aft...

Page 8: ...ling Energy Saving Mode means Bluetooth will broadcast for 2min after keypad lights turn off on Touchscreen Panel after the 2min expires the Bluetooth feature will go into energy savings Sleep mode to reduce some battery draw The front panel will need to be touch to wake up the lock so the Bluetooth connection can be re established Disabling Energy Saving Mode means Bluetooth will stay active cont...

Page 9: ... PIN code 1 Enter Master Mode 2 Enter 1 to select Modify Master Pin Code 3 Enter NEW 4 10 Digit Master PIN Code followed by 4 Repeat Step 3 to confirm NEW Master PIN Code User must change Factory Set Master Pin Code before changing any other menu Settings when first installed Settings will be locked until this has been completed Record Master Pin Code in a safe and secure location as the Alfred Hom...

Page 10: ...ck will time out If you make a mistake during the process you can press the once to go back to previous menu Before entering New User PIN code lock will announce how many User PIN codes already exist and User PIN code number you are registering LOCK OPERATIONS Add Access Card Access Card can be added in Master Mode Menu at the Lock only Master Mode Menu Instructions 1 Enter Master Mode 2 Enter 2 t...

Page 11: ... Master Mode Menu Instructions 1 Enter Master Mode 2 Enter 3 to enter delete User menu 3 Enter 3 to delete Access Card 4 Enter Access Card number followed by or swipe Access card 5 To continue deleting Access Card repeat steps 4 Auto re lock settings Auto Re Lock Feature can be programmed in Settings options on the Alfred Home App or in Master Mode Menu at the Lock Master Mode Menu Instructions 1 ...

Page 12: ...u at the lock Master Mode Menu Instructions 1 Enter Master Mode 2 Enter 6 to enable Away Mode Languages 1 English 2 Spanish 3 Portuguese 4 French 5 Chinese In Away Mode all User PIN codes will be disabled temporarily Device can only be unlocked by Master PIN Code or Zigbee Away Mode will be disabled automatically once Master PIN Code or Zigbee Centered Control Platform If someone unlocks the door ...

Page 13: ... will need to be touched to wake up the lock so the Bluetooth connection can be re established Bluetooth Settings Power Save Optional Alfred Z Wave or other Network Module is required to enable this feature sold separately If the Lock is connected to a network controller it is recommended that all programming of PIN Codes and settings is completed through 3rd party user interface to ensure stable ...

Page 14: ...e 7 Bluetooth settings 8 Network settings 1 Add user PIN code 1 Delete user PIN code 1 Disable 2 Enable 30secs 1 English 2 Spanish 3 Portuguese 4 French 5 Chinese 6 Disable speaker 1 Enable Bluetooth 2 Disable Bluetooth 1 Pair 2 Unpair PROGRAMMING TREE FOR MASTER MODE MENU 3 60secs 4 120secs 5 180secs 12 15 ...

Page 15: ...ti Function button on the Back Assembly or by turning the thumb turn Thumb turn will be in the horizontal position when locked 2 Lock the door from inside Lock the door 1 Lock the door from outside Auto Re lock Mode Manual Mode Press and hold any key on keypad for 1 second Auto Re lock Mode Manual Mode If Auto Re Lock Mode is enabled the latch bolt will be extended and locked automatically after a...

Page 16: ...ode is still intact but to a stranger it cannot easily be guessed Use Emergency USB C Power Port and Reboot Button USB C Power Port Reboot Button Power bank USB C Not included in package In the scenario where the Locks batteries are completely warn out and the lock will no longer turn on you can connect any standard USB C power banks to the Emergency Power port located on both side of the Touch sc...

Page 17: ... hold the reset button 4 Keep holding the reset button and remove a battery from battery box then replace it 5 Keep holding the reset button down until you hear the lock beep Can take up to 10 seconds CAUTION Reset operation will delete all user setting and credentials Master PIN code will be restored to default 12345678 For support please reach out to support alfredinc com You can also reach us a...

Page 18: ...que subi même si le brouillage est susceptible d en compromettre le fonctionnement l appareil numérique du ciem conforme canadien peut 3 b nmb 3 b This device meets the exemption from the routine evaluation limits in section 2 5 of RSS 102 and compliance with RSS 102 RF exposure users can obtain Canadian information on RF exposure and compliance cet appareil est conforme à l exemption des limites ...