Method of Operation  
 
Connect the power: 
Connecting the power, the unit will start to work when it is plugged in. The initial mode will be 
medium-fan-mode (without ionizer function).  
 
Anschluss des Netzkabels: 
Once the power cord is connected , the unit starts to work in medium-fan-mode, the 
ionizer is turned off, the LEDs light up briefly and the particle sensor is activated. 
 

 

On / Off-button: Pressing the power button, the unit will be switched off/on.  
If the unit is switched on again, the last selected mode will be activated and could be changed then. 

 

 

Fan Speed-button: Press the button for selection of fan speed. The LED screen will indicate one 
sign for low speed, two for medium and three for high and a sign for the PM 2,5 -Sensor-controlled 
automatic operation. 

 

Press the button to use the timer function. According your selection, the air cleaner will run for 4, 8 
or 12 hours. The Timer-Function can be combined with all other functions. 

 

If the Sleep-Mode is selected, the air cleaner works very quiet with reduced air quantity. All LEDs will 
be switched off after 10 seconds, except of the one for indication the sleep mode. So the LEDs do 
not interfere in the dark in the room. 
The sleep-Mode can be combined with timer-function and / or ionizer. By pressing any button, the 
sleep-mode will be switched off. 
 

 

Press the button for Ionizer. The LED will show the operation. 
 
 
External timer: The air cleaner can be connected with external timer to set the working time. The 
unit has to be switched on. The initial mode will be medium-fan-speed with switched of ionizer. The 
external timer is not included in the scope of delivery. 
 
 
 

Air quality indication and AUTO-Mode with intelligent PM 2.5 - Sensor Control 

 

 

1.  The air purifier measures the air quality  by using an intelligent dust 

sensor and displays it in color: 
blue = clean air 
yellow = deterioration of air quality 
red = high air pollution

 

The as fine dust (PM2.5) called dust fraction contains 50% of the particles having a diameter of 2.5 microns, a higher 
proportion of smaller particles and a lower proportion of larger particles. Particles of this size can go up in the air sacs. 
They are at most as large as bacteria and therefore cannot be seen with the naked eye. 

The air quality assessment already takes into account the guideline by the WHO (World Health Organization) valid 
from 2020. That means, that the PM 2.5 value will be below 20 ug / m3 for the indication of clean air (blue) 

For an optimal and sustainable air cleaning result we recommend the use as described under item 1 and 6. 

 

 

 
 

Summary of Contents for ALR300 Comfort

Page 1: ...a Artikel für Allergiker Handels GmbH Carl Spitzweg Str 3 D 50127 Bergheim Tel 0 22 71 98 03 09 Fax 0 22 71 98 02 37 eMail verkauf alfda de Web www alfda de Our WEEE Reg Nr DE 87819261 date September 2015 subject to change alfda A manual in German language could be get by download http www allergiker shop alfda de katalog downloads Manual DE ALR300Comfort pdf Table of contents 1 Short notes for th...

Page 2: ...o be damaged Never block the air intake and the air outlet of the unit Place the air purifier not in the area of heatings stoves etc and avoid grease aerosols heat and splash in and at the unit Please unplug the power cord when the unit is not used for a long time To clean the housing do not use water or detergent to avoid damage 3 Function and property Pre plastic filter with a mesh size of less ...

Page 3: ...rotection class II Applicable area optimal maximal Up to 40 m2 100 m3 up to 60 m2 150 m3 5 Components 1 Air intake 2 Air outlet 3 Pedestal 4 Ionizer 5 Carrying handle 6 Power cable 7 label 8 PM 2 5 Dust sensor Operation panel on top of the unit 9 Front panel 10 Plastic Pre Filter 11 Filter Set blue cotton filter HIMOP HEPA filter 12 Indication of air quality 13 Operation panel 14 IR Sensor for rem...

Page 4: ... not suitable to be placed in production areas Please notice the following samples for placing the air leaner because this is important for a good cleaning result If the room size is larger than 60 m2 150 m3 or the room is very winding you may place two air cleaners One air cleaner with much more than 300 m3 h air quantity makes a good cleaning result all over the room area difficult and could cau...

Page 5: ...the dark in the room The sleep Mode can be combined with timer function and or ionizer By pressing any button the sleep mode will be switched off Press the button for Ionizer The LED will show the operation External timer The air cleaner can be connected with external timer to set the working time The unit has to be switched on The initial mode will be medium fan speed with switched of ionizer The...

Page 6: ...tallation of the filter Before using the air cleaner the first time remove the foil packing from the filters inside 1 Remove the front panel as shown 2 Press down on the two mounts of the prefilter and remove the pre filter 3 Remove the filter set as shown and remove the foil packing 4 Place the filter back in and fasten the front panel Note If the front panel is not installed correctly the air cl...

Page 7: ...ained from authorized dealers 11 Failure and Solutions Please refer to the following before contacting Customer Service Centre for service repair Unit does not work Check if the power cord is plugged in correctly power is available and the front panel is installed correctly The Remote Control does not work Please check whether the battery is placed correctly and has enough capacity Probably change...

Page 8: ...orized service Unauthorized attempts to repair Submission in not safety packaging Furthermore no subject to any warranty are batteries and filter cartridges as these are consumable parts From the scope of the guarantee for not or no longer detected defects or damage to the equipment we fix a fee For a custom quote please contact our customer service In this case shipping and handling charges are a...

Reviews: