S e i t e
2 | 8
1. Short notes for the use
The air purifier alfda ALR160 is easy to use. In addition to the built-in timer function, it can be controlled with an external
conventional time switch, to turn it on or off.
For effective air cleaning, we recommend to proceed as follows:
Ventilate extensively 2 - 3 times daily, and then turn on the air cleaner.
In order to achieve an optimal air cleaning, the air cleaner should be operated as long as necessary to achieve
twice the purification of the room air volume.
Examples for running times
:
Room size
minimum running time
fan speed
~10 m² / 25 m³
~ 45 Min.
1 (low)
~10 m² / 25 m³ ~ 20 Min.
3 (high)
~20 m² / 50 m³ ~ 50 Min.
2 (medium)
~20 m² / 50 m³ ~ 40 Min.
3 (high)
~30 m² / 75 m³
~ 80 Min
2 (medium)
~30 m² / 75 m³
~ 60 Min.
3 (high)
Using in a sleeping room:
We
recommend limited running time at high fan speed after airing of the room and before
going to bed. If necessary, you can use the sleep mode the entire night. The window can remain open. In the case of
pollen, place the air cleaner between the open window and the bed area.
We recommend using the ionization only for a short time in the sleeping area, as this can cause poor sleep for sensitive
people.
2. Safety instructions
Please unpack the filter before use, otherwise there will be no filter effect and the air purifier can also be damaged!
Never block the air intake and the air outlet of the unit.
Do not place the air purifier nearby heaters, stoves, etc. and avoid grease aerosols, heat and water splashes in and
near the unit.
Please unplug the power cord when the unit is not used for a long time.
To clean the housing do not use water or detergent to avoid damage.
3. Technical Data *)
Model
ALR160
Voltage
220-240V 50 Hz
Power min. / max. ca.
18 / 31 Watt
Power Standby
1,07 Watt
Air volume Sleep | min. / medium / max. ca.
69 / 120 / 163 m³/h
Noise level Sleep | min. / max. ca.
23,3 / 39,3 dB(A)
Net weight / Gross weight ca.
4,8 / 5,8 kg
Dimensions (L x B x H)
329 x 174 x 509 mm
Cabel length ca.
1,4 m
Insulation
Protection class II
Applicable area optimal / maximal
Up to 15 m² (37,5 m³) / up to 30 m² (75 m³)
*) based on unused alfdaCleanAIR-Filter.
!