24 

 

 

 

Dynamic range:

 set the dynamic range (default 5,0-8 optional). 

Shutter speed:

 active when it is status of manual or shutter-priority (default 1/100

1/25

1/30

1/50

1/60

1/90

1/100

1/120

1/180

1/250

1/350

1/500

1/1000

1/2000

1/3000

1/4000

1/6000

1/10000 optional).   

 

 

Aperture value:

 Set the aperture value, active when it is status of manual or aperture-priority(default F1.8,closed, F11, 

F9.6,F8.0,F6.8,F5.6,F4.8,F4.0,F3.4,F2 .8,F2.4,F2.0,F1.8 optional). 

Brightness:

 Set the brightness value, active when it is a state of brightness priority (default 7,0-23 optional). 

 

color: White balance, saturation, color, white balance, sensitivity, color temperature, gain red and blue gain can be 

set. 

 

White balance modes:

 Set the white balance mode (the default automatic,3000K,4000K,5000K,6500K, manual, 

One-push optional). Note: Click the “Correction” button when selected the One-push white balance mode. 

 

 

 

 

   Saturation:

 Set the saturation (default 80%,60%,70%,80%,90%,100%,110%,120%,130%, optional). 

   Auto white balance Sensitivity:

 Sensitivity Auto white balance settings (default is low, high, medium optional). 

   Chroma

: Set the chrome (default 7,0-14 optional). 

   

Color Temperature: 

set color temperature (Default setting: High, with low, middle for options)   

   Red Gain

: Set the red gain, effective when it is manual (default 255,0-255 optional). 

   

Blue Gain:

 Sets the Blue gain, effective when it is manual (default 199,0-255 optional). 

 

      

 

 

d. Image: Brightness, contrast, sharpness, black and white mode, the gamma curve, Horizontal Flip and Vertical 

Flip can be set. 

 

 

 

Brightness:

 Set the brightness (default 6,0-14 optional). 

 

 

 

Contrast:

 set the contrast (default 8,0-14 optional). 

 

 

 

Sharpness

: Set the sharpness value (default 

7

, 0-15 optional). 

 

 

 

Black and white mode:

 Set black and white mode (default color, black/white optional). 

 

 

 

Gamma

: Gamma value setting (default,0.45,0.50,0.52,0.55 optional). 

 

 

 

Flip Horizontal

: Set Flip Horizontal (default Off, On optional). 

 

 

 

Flip Vertical:

 Set vertical flip (default Off, On optional). 

                

e. Noise Reduction: 2D noise reduction,3D noise reduction and dynamic dead pixel correction available. 

 

 

 

2D Noise Reduction

: Set 2D noise reduction level (default Auto,1-7 and Off optional). 

 

 

    

3D Noise Reduction

: Set 3D noise reduction level (default 

5

,1-

8

 and Off optional). 

 

 

 

Dynamic dead pixel correction:

 Set Dynamic dead pixel correction (default Off,1-8 optional). 

 

 

 

Note: Click “Refresh “to make revision of any video parameters of a, b, c, d, e effective. 

     

 

 

4) Character-Overlapping 

 

 

Display date and time:

 Set whether to display the time and date (default display). 

 

 

Display Title:

 Set whether to display the title (default display). 

 

 

F

ont Color of Time:

 Set font color of time and date (default white, black, yellow, red, blue 

  optional). 

 

 

F

ont Color of Title:

 Set font color of title (default white, black, yellow, red, blue optional). 

 

 

Moving characters

: Set the display position of moving date, time and title, click on the "up, down, left, right" 

buttons to move the corresponding character position. 

        

Title Content:

 Set title content (default CAMERA1). 

        

Time Content:

 Set time content (default 1970/01/10 05:36:00) 

 

    Click on the "Save" button and display the "Save successful" message, then valid

 

5)Character Size 

Mainstream character size: Set the character size of the display, the device will restart 

automatically after changed and saved (default 24,24,16 optional) 

Secondary stream character size: Set the character size of the display, the device will restart automatically after changed 

and saved (default 16,24,16 optional) 

Click on the "Save" button to display "Parameter saved successfully" message, set to take effect 

 

6)Video output 

Output Format: Set the video output format (default 

1080P60,1080P50,1080P30,1080P25,1080I60,1080I50,720P60,720P50,720P30,720P25,1080P59.94,1080I59.94,1080P

29.97,720P59.94,720P29.97 optional). 

Click on the "Save" button, it will be valid when display "Save successful". 

 
4.2.6 Network configuration 

1) Network port 

Data port:

 set the data port, the device will restart automatically after changed (default 3000,0-65535 optional). 

Web Port

: Set Web port, the device will restart automatically after changed (default is 80,0-65535 is optional). 

Onvif Port

: Set Onvif port, the device will restart automatically after changed (default 2000,0-65535 optional). 

Soap Port

: Set Soap port (default 1936,0-65535 optional). 

RTMP Port:

 Set RTMP port (default 1935,0-65535 optional). 

Summary of Contents for ALF-12X-NDIC

Page 1: ...1 www alfatronelectronics com ALFATRON ELECTRONICS GmbH GERMANY ALF 12X NDIC ALF 20X NDIC ALF 30X NDIC Full HD PTZ Camera User Manual...

Page 2: ...er or an experienced radio TV technician for help WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipme...

Page 3: ...ong or corrosive detergents to avoid scratching the lens and affecting the image This product has no parts that users can repair by themselves and the damage caused by users self disassembly does not...

Page 4: ...not be tilted otherwise the picture may be skewed Installation ensures that there are no obstacles in the rotating range of the platform to prevent damage to the rotating shaft of the structure Do not...

Page 5: ......

Page 6: ...4 3 RS 232 Interface 9 3 Application Instruction 10 3 1 Video Output 11 3 1 1 Power On Initial Configuration 11 3 1 2 Video Output 11 3 2 Remote Controller 11 3 2 1 Keys Instruction 11 3 2 2 Applicati...

Page 7: ...26 5 1 1 Camera return command 26 5 1 2 Camera control command 27 5 1 3 Inquiry command 29 5 2 Pelco D protocol command list 31 5 3 Pelco P protocol command list 31 6 Camera Maintenance and Troublesho...

Page 8: ...receiver light stops blinking the self checking is finished Note If you set preset 0 when Power on self test is completed the camera automatically moves to the preset 0 position 1 3 Video Output Vide...

Page 9: ...ATRON ALF 12X NDIC ALF 20X NDIC and ALF 30X NDIC 3 1 4 Bracket mount Note Bracket can only be wall mounted or ceiling mounted on a concrete wall and cannot be installed on plasterboard 1 Wall mount st...

Page 10: ...ALFATRON ALF 12X NDIC ALF 20X NDIC and ALF 30X NDIC 4 2 Ceiling mount steps...

Page 11: ...roduct Introduction 2 1 2 Dimension Camera dimension 2 1 3 Accessory When you unpack check that all the supplied accessories are included Standard 1x Power adapter 1x RS232 cable User manual 4x Double...

Page 12: ...uts support HDMI 3G SDI USB wired LAN and wireless LAN interfaces The 3G SDI is available for 100m transmission at 1080p60 format 7 Multiple Remote Controls There is IR remoter and 2 4G wireless remot...

Page 13: ...c Shutter Auto Manual BLC ON OFF WDR OFF Dynamic level adjustment Video Adjustment Brightness Color Saturation Contrast Sharpness B W mode Gamma curve SNR 55dB Input Output Interface Video Interfaces...

Page 14: ...95 Working temperature 10 50 Working humidity 20 80 Dimension 150mmX150mmX167 5mm Weight 1 4KG Remote Operation IP Remote Upgrade Reboot and Reset Accessories Accessories with camera 12V 1 5A power su...

Page 15: ...ble 2 2 Dial Switch setting 2 4 3 RS 232 Interface 1 RS 232C interface specification as shown below Computer or keyboard and camera connection method Camera WindowsDB 9 1 DTR 1 DCD 2 DSR 2 RXD 3 TXD 3...

Page 16: ...nd output interface so you can cascade as shown above 3 Application Instruction NO Port Definition 1 DTR Data Terminal Ready 2 DSR Data Set Ready 3 TXD Transmit Data 4 GND System Ground 5 RXD Receive...

Page 17: ...nterface then the monitor output image 3 2 Remote Controller 3 2 1 Keys Instruction 1 Standby Key After 3S long press the camera will step into standby mode Long press 3S again the camera will self te...

Page 18: ...te controller button the indicator light is flashing release the button the indicator light stops flashing Users can control the pan tilt zoom setting and running preset positions via the IR remote co...

Page 19: ...reset Note 10 preset positions in total are available by remote controller 2 Preset Running Press a number key 0 9 directly to run a relative preset Note Action in vain if a relative preset position i...

Page 20: ...inter to the Setup in the Main Menu click the HOME key and enter into the System Setting as shown below PROTOCOL VISCA Pleco P Pleco D Auto Visca ADDR VISCA 1 7 Pelco P 1 255 Pelco D 1 255 Baud rate 2...

Page 21: ...ON BLC ON OFF for options only available in auto mode Anti Flicker OFF 50Hz 60Hz for options only available in Auto Iris priority Brightness priority modes Gain Limit 0 15 only available in Auto Iris...

Page 22: ...100 110 120 130 Hue 0 14 AWB Sensitivity high middle low Color Style Default style1 4 Color Temp high middle low 3 IMAGE Move the pointer to the IMAGE in the Menu click the HOME and enter the IMAGE as...

Page 23: ...e 1 7 3D Noise Reduction Close 1 8 Dynamic Hot Pixel Close 1 5 3 3 4 P T Z Move the pointer to the P T Z in the Main Menu click the HOME and enter the P T Z as follow Depth of Field Only effective for...

Page 24: ...sion Move the pointer to the VERSION in the Main Menu click the HOME and enter the VERSION as follow MCU Version Display MCU version information Camera Version Display camera version information AF Ve...

Page 25: ...ty lowered by unstable signal transmission due to poor contact of cables The computer must have the network segment where the camera IP address belongs to The device will not be accessible if without...

Page 26: ...dress to be added cannot be same with that of other computers or devices The existence of this IP address needs to be verified before adding Click the Start and select Operation to input cmd as pictur...

Page 27: ...login as administrator and normal user If login as administrator Default User name Password admin users can preview playback configuration and cancel in the Web Client If login in as normal user Defau...

Page 28: ...file Image File and click Search and search out the video file click Play to play the image file 4 2 4 Configuration Click Configuration to enter the device parameters setting page There are the follo...

Page 29: ...tream 1 300F optional secondary stream 1 150F optional Stream Name When streaming via rtsp or rtmp user can modify stream name Mainstream live av0 sub stream live av1 Click the Save button to display...

Page 30: ...l correction available 2D Noise Reduction Set 2D noise reduction level default Auto 1 7 and Off optional 3D Noise Reduction Set 3D noise reduction level default 5 1 8 and Off optional Dynamic dead pix...

Page 31: ...1 Register Username IPC Register Password 12345678 Equipment ownership Users can add their own Administrative regions Users can add their own Alarm Zone Users can add their own Equipment installation...

Page 32: ...is complete you need to restore factory defaults a through web to restore the factory default configuration b through the recovery menu c remote control shortcut 6 Choose one of the above three ways...

Page 33: ...Variable 8x 01 04 08 2p FF p 0 low F high Near Variable 8x 01 04 08 3p FF Direct 8x 01 04 48 0p 0q 0r 0s FF pqrs Focus Position Auto Focus 8x 01 04 38 02 FF One Push Mode 8x 01 04 38 04 FF Manual Foc...

Page 34: ...E 00 00 0p 0q FF pq ExpComp Position CAM_Back Light On 8x 01 04 33 02 FF Back Light Compensation Off 8x 01 04 33 03 FF CAM_WDRStrength Reset 8x 01 04 21 00 FF WDR Level Setting Up 8x 01 04 21 02 FF Do...

Page 35: ...speed 0x01 low speed to 0x18 high speed WW Tilt speed 0x01 low speed to 0x14 high speed YYYY Pan Position ZZZZ Tilt Position Down 8x 01 06 01 VV WW 03 02 FF Left 8x 01 06 01 VV WW 01 03 FF Right 8x 0...

Page 36: ...0Hz 2 60Hz CAM_ApertureInq 8x 09 04 42 FF y0 50 00 00 0p 0q FF pq Aperture Gain CAM_PictureEffectModeInq 8x 09 04 63 FF y0 50 00 FF Off y0 50 04 FF B W CAM_MemoryInq 8x 09 04 3F FF y0 50 0p FF p Memor...

Page 37: ...Pan Speed Tilt Speed SUM DownLeft 0xFF Address 0x00 0x14 Pan Speed Tilt Speed SUM DownRight 0xFF Address 0x00 0x12 Pan Speed Tilt Speed SUM Zoom In 0xFF Address 0x00 0x20 0x00 0x00 SUM Zoom Out 0xFF A...

Page 38: ...ion Response 0xA0 Address 0x00 0x59 Value High Byte Value Low Byte 0xAF XOR Query Tilt Position 0xA0 Address 0x00 0x53 0x00 0x00 0xAF XOR Query Tilt Position Response 0xA0 Address 0x00 0x5B Value High...

Page 39: ...be displayed menu will automatically exist 30s later then it can be controlled by remote controller 5 Serial port cannot work a Check whether the camera serial device protocol baud rate address is con...

Page 40: ...cturer s product specific warranties against any defect attributable to faulty workmanship or materials fair wear and tear being excluded 1 7 This limited warranty only covers the cost of faulty goods...

Page 41: ...ity or condition of the goods or their failure to correspond with specification shall be notified in writing to the Company within 7 days of delivery or where the defect or failure was not apparent on...

Reviews: