Alfa Network ALP 44 User Manual Download Page 1

48X48 MM DIMENSION 

4MS (250 TIMES PER SECOND) SAMPLING TIME 

2 ROW, 4 DIGITS DISPLAY 

2 PIECES RELAY OUTPUT  (SINGLE AND DOUBLE 
CONTACT) 

SELECTABLE OUTPUT TIME 

ADJUSTABLE SCREEN REFRESH RATE 

ENTERING OF HYSTERESIS  

SELECTABLE POINT POSITION 

TARE FUNCTION (ABS/REL) 

%0,1 ACCURACY 

ENTERING OFFSET VALUE 

PASSWORD PROTECTION 

U

SER 

M

ANUAL

 

MEASUREMENT

   

INSTRUMENTS

                    

 

A

LP 

44

 

Potentiometric (ALP44P) 

0-10 V (ALP44V) 

4-20 mA (ALP44A) Analogue Input 

Iran agent

a

Tel:  021 66 3939 00
Mob: 0912 147 3023
www.IranAtek.ir

Summary of Contents for ALP 44

Page 1: ...UTPUT TIME ADJUSTABLE SCREEN REFRESH RATE ENTERING OF HYSTERESIS SELECTABLE POINT POSITION TARE FUNCTION ABS REL 0 1 ACCURACY ENTERING OFFSET VALUE PASSWORD PROTECTION USER MANUAL MEASUREMENT INSTRUME...

Page 2: ...ection of point position decp 7 4 4 Entering of scale value s lo s hi 7 4 5 Automatic calibration fcal 8 4 6 Manuel calibration c lo c h 8 4 7 Span menu span 9 4 8 Reset selection tare 9 4 9 Entering...

Page 3: ...V 0 4 20 mA Current Input ALP44A OUTPUTs Analogue 0 10 V Optional 4 20 mA Optional OUTPUTs Contact 2 unit 250 VAC 3A for Resistive Load Relay Serial Communication RS 232 Optional PHYSICAL CHARACTERIST...

Page 4: ...f fall snap shake during working 4 Make Sensor connections without energy on the device do not connect in any way during operation 5 Make sure that is shielded cables between device and sensor 6 Do no...

Page 5: ...3...

Page 6: ...4...

Page 7: ...On while Set 2 value is displayed in the bottom display 7 LED of TARE LED status of Tare Absolute Relative Function Button Functions 8 PROG Button Operating Mode Used to return to the menu with Tare...

Page 8: ...The top row shows the name of the menu and bottom row also yellow marked selected value in menu content Set 1 set 2 allows controlling to out1 and out2 relays Move to the desired set point for setting...

Page 9: ...xample this provides that a potentiometer is shown 0 or others value at minimum position stroke length or others value at maximum position Likewise this situation also applies to the pressure transmit...

Page 10: ...nus C LO menu provides to entered minimum position value C HI menu also entered maximum position value C LO menu sets the potentiometer is in the closed position and also C HI menu sets in the opened...

Page 11: ...ssed at Span menu bottom row menu content flashes Change the choice with up down buttons Tare function will be active at on position and also inactive at off position Save selection with prg button T1...

Page 12: ...s situations If password is incorrect you cannot make any change Password is not requiered while secu menu is off SPS1 menu is added to menu titles while Secu menu is nset position SPS2 menu is also a...

Page 13: ...7600 bps Data bits 8 Stop bits 1 Parity none 999999 message is displayed on the screen when value is too high Scale or format value can be minimized 999999 message is displayed on the screen when valu...

Page 14: ...tput 4 20 mA Output Serial No This product is guaranteed for two years against manufacturing defects Conditions out of the warranty Mechanical damage Shipping damage Users error Other situations are c...

Page 15: ...evizli Mah Bagdat Cad Guven Sok No 11 TR 34846 Maltepe Istanbul TURKEY Tel 90 216 399 44 04 Fax 90 216 399 44 02 Web www ateksensor com E Mail info ateksensor com Iran agent a Tel 021 66 3939 00 Mob 0...