Assembly of body parts
2. Mount assembled gear ring in body (Pos. 13.1). Tighten screws (Pos. 13.5) using the torque
wrench (TTE81B157) to maximum 5 Nm. Too much torque breaks the screws.
3. Preparation of O-rings before mounting: Dip the O-rings in water. If water is not used then be
very careful about how the O-rings behave when screwing the cone onto the stem.
4. Mount the O-ring (Pos. 9) in the O-ring grove on the outside of body. (Pos. 13.1). If the length
of O-ring does not fit precisely to the O-ring groove, then you can stretch the O-ring.
5. Mount the O-ring (Pos. 10) in the O-ring groove inside the body (Pos. 13.1).