Page 64
Instruction Manual, Alfa Laval Toftejorg SaniJet 25
Standard machines, machines delivered with Q-Doc and/or ATEX certification, Dir. 94/9/EC
IM-TE91A760_EN12
Assembly of lower parts
4. Preparation of O-rings (Pos. 16 and 17) before mounting: Dip the O-rings in water. If water is
not used then be very careful about how the O-rings behave when screwing the cone onto the
stem.
5. Mount O-ring (Pos. 16) in groove inside nozzle head (Pos. 18)
6. Preparation before mounting the bevel gear (Pos. 14) on nozzle head (Pos. 18): It is
recommended to grease the nozzle head thread with food graded/FDA compliant grease. The
grease reduces the risk for galling in threads. The grease is enclosed between the O-rings
and, therefore, it will not come into contact with the cleaning media.
Be very careful not to put grease onto the O-rings as the o-rings swells in contact with
grease!
If the food graded/FDA compliant grease is not allowed into the SaniJet 25 for some reason, it
is recommended to be very careful when joining threaded parts.
7. Mount the ball retainer with balls (Pos. 5) in the groove on the hub nut (Pos. 15).
Summary of Contents for Toftejorg SaniJet 25
Page 2: ......