Installation
(continued)
Connection
Wiring diagram
Note:
The Down pipe shall rotate clockwise (CW) as viewed from above (from the motor), and
accordingly the output shaft from the gear must rotate clockwise as viewed from the shaft side.
The directions of motor
rotation is as viewed from
motor output shaft side.
As the HS gear (1:36) reverses the rotation whereas the HS gear (1:75) does not, the internal wiring is
connected differently from the factory in order to compensate for this. All you have to do is to connect
the power to the two terminals in the middle on the terminal strip and mount grounding with a spring
washer to the grounding point.
Note:
Insulation class of this motor is B.
Make sure that the motor case temperature does not exceed 100°C during operation of the motor.
Operation exceeding case temperature 100° may significantly deteriorate the coils and ball bearings
of the motor and shorten motor’s life span. Motor case temperature can be measured by fixing a
thermometer on the motor surface. It can also be measured using thermo tape or thermocouple.
Note:
Single–phase motors use a capacitor and keep it connected even after rotation of the motor
has started.