![Alfa Laval SRU series Instruction Manual Download Page 12](http://html1.mh-extra.com/html/alfa-laval/sru-series/sru-series_instruction-manual_2895192012.webp)
4 Installation
To ensure optimum operation it is important that any pump unit is installed correctly. When designing a pumping system the
following should be taken into consideration.
Coupling alignment:
Before the pump unit is installed is it important to ensure that the mounting surface is flat to avoid distortion of the baseplate,
which may cause pump/motor shaft misalignment and pump/motor unit damage. Once the baseplate has been secured, the
pump shaft to motor shaft coupling alignment should be checked and adjusted as necessary. This is achieved by checking
the maximum angular and parallel misalignment for the couplings as stated below. Shaft alignment that is outside the stated
tolerances can be corrected by applying shims under the motor or pump foot, or, by moving the pump or drive sideways on
the baseplate. All bolts that have been loosened should be re-tightened to the stated torque figure.
The following dimensions and tolerances apply to standard supply couplings only.
Parallel misalignment
Measure 4 positions at 90° around coupling
Coupling size
Dimension A Maximum
70
0.3 mm
90
0.3 mm
110
0.3 mm
130
0.4 mm
150
0.4 mm
180
0.4 mm
230
0.5 mm
280
0.5 mm
TD 246-090
A
Angular misalignment
Measure 4 positions at 90° around coupling
Coupling size
Dimension B Maximum
70
1°
90
1°
110
1°
130
1°
150
1°
180
1°
230
1°
280
1°
TD 246-089
B
o
Assembled length
Coupling size
Dimension L ± 1.0mm
70
25
90
30.5
110
45
130
53
150
60
180
73
230
85.5
280
105.5
TD 246-088
L
Recommended bolt torques.
Thread Diameter
M6
M8
M10
M12
M16
M20
M24
Torque (Nm)
6
15
30
50
120
250
200
12