In USCG mode, the flow is regulated to be as high as possible to fully treat the
water. Between UVI value
a
and
b
, the flow is regulated be between 50 % and
100 % of full flow capacity. The higher UVI value (cleaner water) the the higher
flow.
In IMO mode, the flow is always 100 % above compliant limit. But when UVI
falls below the compliant limit, the flow is decreased to maximum 50 %
2.2.2.2 Power optimization
The purpose is to save power by dimming the lamps to minimum power
required to fully treat the water. Power is regulated when the UVI in the water
is between
c
and
d
(see graph above). The power output is regulated between
50 % and 100 % of full power.
2.2.2.3 Power optimization during special conditions
• Start-up and the first two minutes of ballast/deballast: The UV lamps are lit
to 100 % to ensure treatment before values from the UV sensor are stable.
• Stop: UV lamps are lit to 100 % for 10 seconds before they are stopped.
This will prolong the life of the lamps
• Stripping: The lamps are lit to 100 % during the complete stripping process.
This to have an efficient treatment of the deballast water when it is mixed
with the driving water, which has not been treated at ballast.
• Low UV intensity: See Flow control above.
• Broken UV lamp: See Operation with broken UV lamp below.
2.2.2.4 Operation with broken UV lamp
If a UV lamp breaks during operation, the ongoing process continues but is not
compliant. A warning and an additional common alarm is issued and a log is
written to the event log. The operator should act according to the ballast water
management plan. After process is finished, it will not be possible to start a
new process until the broken lamp has been changed.
The flow is decreased to 65% of max flow and the UV lamps are lit to 100 %.
This is done so that the treatment shall correspond to the type approval
requirements.
If a UV lamp breaks during operation, the ongoing process continues but is not
compliant. A warning and an additional common alarm is issued and a log is
written to the event log. The operator should act according to the ballast water
management plan. After process is finished, it will not be possible to start a
new process until the broken lamp has been changed.
The flow is decreased to 65 % in IMO mode and 50 % in USCG mode of max
flow and the UV lamps are lit to 100 %. This is done so that the treatment shall
correspond to the type approval requirements.
If a lamp breaks in standby mode, it is not possible to start a process.
2.2.3 Start-up
Ballasting and deballasting begins with a start-up phase. During start-up, the
UV lamps are warmed up for 90 seconds.
200000695-1-EN-GB
21
System description 2
EN
Summary of Contents for PureBallast 135 Compact USCG
Page 2: ......
Page 13: ......
Page 14: ...1 Safety 200000695 1 EN GB 9 EN Safety ...
Page 20: ...2 System description 200000695 1 EN GB 15 EN ...
Page 43: ...200000695 1 EN GB 38 2 System description EN ...
Page 44: ...3 Operating instructions and control system description 200000695 1 EN GB 39 EN ...
Page 75: ...200000695 1 EN GB 70 3 Operating instructions and control system description EN ...
Page 121: ...200000695 1 EN GB 116 3 Operating instructions and control system description EN ...
Page 122: ...4 Parameters 200000695 1 EN GB 117 EN ...
Page 140: ...5 Alarms and faultfinding 200000695 1 EN GB 135 EN ...
Page 170: ...6 Technical data and drawings 200000695 1 EN GB 165 EN ...
Page 175: ...6 4 1 Graphic symbols used in drawings 200000695 1 EN GB 170 6 Technical data and drawings EN ...
Page 179: ...6 4 2 3 Connection list 200000695 1 EN GB 174 6 Technical data and drawings EN ...
Page 180: ...200000695 1 EN GB 175 Technical data and drawings 6 EN ...
Page 181: ...200000695 1 EN GB 176 6 Technical data and drawings EN ...
Page 184: ...6 4 2 5 Instrument air distribution 200000695 1 EN GB 179 Technical data and drawings 6 EN ...
Page 188: ...200000695 1 EN GB 183 Technical data and drawings 6 EN ...
Page 192: ...6 4 3 3 Electrical cabinet 200000695 1 EN GB 187 Technical data and drawings 6 EN ...
Page 194: ...6 4 3 5 Valve V212 31 optional 200000695 1 EN GB 189 Technical data and drawings 6 EN ...
Page 198: ...200000695 1 EN GB 193 Technical data and drawings 6 EN ...
Page 199: ...200000695 1 EN GB 194 6 Technical data and drawings EN ...
Page 200: ...6 4 3 9 Remote control panel optional 200000695 1 EN GB 195 Technical data and drawings 6 EN ...
Page 201: ...200000695 1 EN GB 196 6 Technical data and drawings EN ...
Page 202: ...6 4 3 10 Air preparation unit optional 200000695 1 EN GB 197 Technical data and drawings 6 EN ...
Page 203: ...6 4 3 11 Transformer optional 200000695 1 EN GB 198 6 Technical data and drawings EN ...
Page 262: ...200000695 1 EN GB 257 Technical data and drawings 6 EN ...
Page 263: ...200000695 1 EN GB 258 6 Technical data and drawings EN ...
Page 264: ...200000695 1 EN GB 259 Technical data and drawings 6 EN ...
Page 265: ...200000695 1 EN GB 260 6 Technical data and drawings EN ...
Page 266: ...200000695 1 EN GB 261 Technical data and drawings 6 EN ...
Page 267: ...200000695 1 EN GB 262 6 Technical data and drawings EN ...
Page 268: ...200000695 1 EN GB 263 Technical data and drawings 6 EN ...
Page 269: ...200000695 1 EN GB 264 6 Technical data and drawings EN ...
Page 270: ...6 4 5 2 Safety data sheet UV lamp 200000695 1 EN GB 265 Technical data and drawings 6 EN ...
Page 271: ...200000695 1 EN GB 266 6 Technical data and drawings EN ...
Page 272: ...200000695 1 EN GB 267 Technical data and drawings 6 EN ...
Page 273: ...200000695 1 EN GB 268 6 Technical data and drawings EN ...
Page 274: ...200000695 1 EN GB 269 Technical data and drawings 6 EN ...
Page 275: ...200000695 1 EN GB 270 6 Technical data and drawings EN ...
Page 276: ...200000695 1 EN GB 271 Technical data and drawings 6 EN ...
Page 277: ...200000695 1 EN GB 272 6 Technical data and drawings EN ...
Page 278: ...200000695 1 EN GB 273 Technical data and drawings 6 EN ...
Page 279: ...200000695 1 EN GB 274 6 Technical data and drawings EN ...
Page 280: ...200000695 1 EN GB 275 Technical data and drawings 6 EN ...
Page 281: ...200000695 1 EN GB 276 6 Technical data and drawings EN ...
Page 282: ...7 Service manual 200000695 1 EN GB 277 EN ...
Page 343: ...4 ...
Page 346: ...2 Electrical cabinet 2921A Book No 7 ...
Page 348: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2922A Book No 9 ...
Page 350: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2950A Book No 11 ...
Page 352: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2951A Book No 13 ...
Page 354: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2953A Book No 15 ...
Page 356: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2954A Book No 17 ...
Page 358: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2955A Book No 19 ...
Page 360: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2692A Book No 21 ...
Page 362: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2956A Book No 23 ...
Page 364: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2958A Book No 25 ...
Page 366: ...2 Module 85 2923A Book No 7 ...
Page 368: ...2 Module 85 2923A Book No 9 ...
Page 370: ...2 1 Sub module small 2 Module 85 3136A ...
Page 372: ...2 1 Sub module small 2 Module 85 2960A ...
Page 374: ...2 1 Sub module small 2 Module 85 2962A ...
Page 376: ...2 1 Sub module small 2 Module 85 3026A ...
Page 378: ...2 1 Sub module small 2 Module 85 3035A ...
Page 380: ...2 1 Sub module small 2 Module 85 3025A ...
Page 382: ...2 1 Sub module small 2 Module 85 2961A ...
Page 384: ...2 2 Pump P320 1 and P321 5 2 Module 85 2606A ...
Page 386: ...2 3 Valve block 2 Module 85 2959A 7 ...
Page 388: ...2 4 Filter regulator 2 Module 85 3091A4 49 ...
Page 390: ...2 5 Junction box 2 Module 85 2957A 51 ...
Page 392: ...2 6 Cable set 2 Module 85 2377A 53 ...
Page 394: ...2 7 Lamp cable set 2 Module 85 2377A 55 ...
Page 396: ...4 Cable set 2377A Book No 9038941 02 Rev 1 57 ...
Page 398: ...5 Valve V212 31 optional 2716A Book No 9038941 02 Rev 1 59 ...
Page 400: ...6 Sampling device EN optional 2780A Book No 9038941 02 Rev 1 61 ...
Page 402: ...7 Remote control panel optional 2875A Book No 9038941 02 Rev 1 63 ...
Page 404: ...7 1 Cover 7 Remote control panel optional 2883A Book No 9038941 02 Rev 1 65 ...
Page 405: ...PureBallast 3 1 85 Compact 8 Extended options SPC 66 Book No 9038941 02 Rev 1 ...
Page 406: ...8 Extended options SPC 2377A Book No 9038941 02 Rev 1 67 ...
Page 408: ...8 1 Transformer optional 8 Extended options SPC 3084A Book No 9038941 02 Rev 1 69 ...