Alarm details
Possible cause
What to do?
A05
EC air temp high
(TT401).
Trigger
: TT401
in electrical cabinet.
Delay
: 15 sec.
Comment
: Temperature
in electrical cabinet over
60 °C.
The inlet and/or outlet
air filter is dirty.
Clean the filters.
Mechanical obstacles.
Check that mechanical parts in the fan can rotate freely.
Ambient temperature is
too hot.
Wait until cooler.
Electrical problem.
Check that all electrical connections are OK and that the
electrical wiring is not damaged. See
on page 209.
A06
EC cabinet air temp
missing (TT401).
Trigger
: TT401 in
electrical cabinet.
Delay
: 5 sec.
Comment
: Signal from
TT401 is missing.
Signal missing or
temperature transmitter
malfunction.
See A05.
Electrical problem.
See A05.
A07
EC cabinet fan error.
Trigger
: Fan speed
counter in electrical
cabinet.
Delay
: 60 sec.
Faulty connection of
signal cable or faulty
cable.
1.
Check cables to the component “M1 fan”. See
Electrical cabinet / Circuit diagram
on page 209.
2.
Check fuse F44B in electrical cabinet.
Obstructions have
entered the fan.
Turn off the power and remove the obstruction.
A10
Process flow signal
missing (FT201-1).
Trigger
: Flow meter
FT201-1.
Delay
: 5 sec.
Comment
: Error in
system flow sensor.
Signal missing or flow
meter FT201-1
malfunction.
1.
Check fuse F43 in electrical cabinet to see what
circuit caused the fuse trip.
2.
Use the circuit diagram for electrical cabinet, in
section
component or find the reason that caused the fuse
trip and attend to it.
3.
Check that all electrical connections are OK and that
the electrical wiring is not damaged.
4.
Check that system flow has not been significantly
over maximum flow for the system.
5.
Replace flow meter FT201-1.
W12
Process flow higher than
certified (FT201-1).
Reduce flow!
Trigger
: FT201-1.
Delay
: 30 sec.
Note
: Operation
continues but is not
compliant and does not
fullfil requirements for
treatment of ballast
water. Act according to
ballast water
management plan.
Flow rate higher than
selected certified flow.
See field certified flow in
on
page 50.
Reduce the incoming ballast water flow to the PureBallast
system.
Wrong setting in
FT201-1
on page 117.
Flow sensor
malfunctions.
See section
Flow meter
page 136.
200000695-1-EN-GB
138
5 Alarms and faultfinding
EN
Summary of Contents for PureBallast 135 Compact USCG
Page 2: ......
Page 13: ......
Page 14: ...1 Safety 200000695 1 EN GB 9 EN Safety ...
Page 20: ...2 System description 200000695 1 EN GB 15 EN ...
Page 43: ...200000695 1 EN GB 38 2 System description EN ...
Page 44: ...3 Operating instructions and control system description 200000695 1 EN GB 39 EN ...
Page 75: ...200000695 1 EN GB 70 3 Operating instructions and control system description EN ...
Page 121: ...200000695 1 EN GB 116 3 Operating instructions and control system description EN ...
Page 122: ...4 Parameters 200000695 1 EN GB 117 EN ...
Page 140: ...5 Alarms and faultfinding 200000695 1 EN GB 135 EN ...
Page 170: ...6 Technical data and drawings 200000695 1 EN GB 165 EN ...
Page 175: ...6 4 1 Graphic symbols used in drawings 200000695 1 EN GB 170 6 Technical data and drawings EN ...
Page 179: ...6 4 2 3 Connection list 200000695 1 EN GB 174 6 Technical data and drawings EN ...
Page 180: ...200000695 1 EN GB 175 Technical data and drawings 6 EN ...
Page 181: ...200000695 1 EN GB 176 6 Technical data and drawings EN ...
Page 184: ...6 4 2 5 Instrument air distribution 200000695 1 EN GB 179 Technical data and drawings 6 EN ...
Page 188: ...200000695 1 EN GB 183 Technical data and drawings 6 EN ...
Page 192: ...6 4 3 3 Electrical cabinet 200000695 1 EN GB 187 Technical data and drawings 6 EN ...
Page 194: ...6 4 3 5 Valve V212 31 optional 200000695 1 EN GB 189 Technical data and drawings 6 EN ...
Page 198: ...200000695 1 EN GB 193 Technical data and drawings 6 EN ...
Page 199: ...200000695 1 EN GB 194 6 Technical data and drawings EN ...
Page 200: ...6 4 3 9 Remote control panel optional 200000695 1 EN GB 195 Technical data and drawings 6 EN ...
Page 201: ...200000695 1 EN GB 196 6 Technical data and drawings EN ...
Page 202: ...6 4 3 10 Air preparation unit optional 200000695 1 EN GB 197 Technical data and drawings 6 EN ...
Page 203: ...6 4 3 11 Transformer optional 200000695 1 EN GB 198 6 Technical data and drawings EN ...
Page 262: ...200000695 1 EN GB 257 Technical data and drawings 6 EN ...
Page 263: ...200000695 1 EN GB 258 6 Technical data and drawings EN ...
Page 264: ...200000695 1 EN GB 259 Technical data and drawings 6 EN ...
Page 265: ...200000695 1 EN GB 260 6 Technical data and drawings EN ...
Page 266: ...200000695 1 EN GB 261 Technical data and drawings 6 EN ...
Page 267: ...200000695 1 EN GB 262 6 Technical data and drawings EN ...
Page 268: ...200000695 1 EN GB 263 Technical data and drawings 6 EN ...
Page 269: ...200000695 1 EN GB 264 6 Technical data and drawings EN ...
Page 270: ...6 4 5 2 Safety data sheet UV lamp 200000695 1 EN GB 265 Technical data and drawings 6 EN ...
Page 271: ...200000695 1 EN GB 266 6 Technical data and drawings EN ...
Page 272: ...200000695 1 EN GB 267 Technical data and drawings 6 EN ...
Page 273: ...200000695 1 EN GB 268 6 Technical data and drawings EN ...
Page 274: ...200000695 1 EN GB 269 Technical data and drawings 6 EN ...
Page 275: ...200000695 1 EN GB 270 6 Technical data and drawings EN ...
Page 276: ...200000695 1 EN GB 271 Technical data and drawings 6 EN ...
Page 277: ...200000695 1 EN GB 272 6 Technical data and drawings EN ...
Page 278: ...200000695 1 EN GB 273 Technical data and drawings 6 EN ...
Page 279: ...200000695 1 EN GB 274 6 Technical data and drawings EN ...
Page 280: ...200000695 1 EN GB 275 Technical data and drawings 6 EN ...
Page 281: ...200000695 1 EN GB 276 6 Technical data and drawings EN ...
Page 282: ...7 Service manual 200000695 1 EN GB 277 EN ...
Page 343: ...4 ...
Page 346: ...2 Electrical cabinet 2921A Book No 7 ...
Page 348: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2922A Book No 9 ...
Page 350: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2950A Book No 11 ...
Page 352: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2951A Book No 13 ...
Page 354: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2953A Book No 15 ...
Page 356: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2954A Book No 17 ...
Page 358: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2955A Book No 19 ...
Page 360: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2692A Book No 21 ...
Page 362: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2956A Book No 23 ...
Page 364: ...2 1 Electrical cabinet subas 2 Electrical cabinet 2958A Book No 25 ...
Page 366: ...2 Module 85 2923A Book No 7 ...
Page 368: ...2 Module 85 2923A Book No 9 ...
Page 370: ...2 1 Sub module small 2 Module 85 3136A ...
Page 372: ...2 1 Sub module small 2 Module 85 2960A ...
Page 374: ...2 1 Sub module small 2 Module 85 2962A ...
Page 376: ...2 1 Sub module small 2 Module 85 3026A ...
Page 378: ...2 1 Sub module small 2 Module 85 3035A ...
Page 380: ...2 1 Sub module small 2 Module 85 3025A ...
Page 382: ...2 1 Sub module small 2 Module 85 2961A ...
Page 384: ...2 2 Pump P320 1 and P321 5 2 Module 85 2606A ...
Page 386: ...2 3 Valve block 2 Module 85 2959A 7 ...
Page 388: ...2 4 Filter regulator 2 Module 85 3091A4 49 ...
Page 390: ...2 5 Junction box 2 Module 85 2957A 51 ...
Page 392: ...2 6 Cable set 2 Module 85 2377A 53 ...
Page 394: ...2 7 Lamp cable set 2 Module 85 2377A 55 ...
Page 396: ...4 Cable set 2377A Book No 9038941 02 Rev 1 57 ...
Page 398: ...5 Valve V212 31 optional 2716A Book No 9038941 02 Rev 1 59 ...
Page 400: ...6 Sampling device EN optional 2780A Book No 9038941 02 Rev 1 61 ...
Page 402: ...7 Remote control panel optional 2875A Book No 9038941 02 Rev 1 63 ...
Page 404: ...7 1 Cover 7 Remote control panel optional 2883A Book No 9038941 02 Rev 1 65 ...
Page 405: ...PureBallast 3 1 85 Compact 8 Extended options SPC 66 Book No 9038941 02 Rev 1 ...
Page 406: ...8 Extended options SPC 2377A Book No 9038941 02 Rev 1 67 ...
Page 408: ...8 1 Transformer optional 8 Extended options SPC 3084A Book No 9038941 02 Rev 1 69 ...