1 Description
1.4
Design
The Pharma-line S is in hygienic design in line with ASME BPE, USP and cGMP requirements.
The Pharma-line S has no dead-legs and is fully drainable on the product side. All product wetted parts in the Pharma-line S are
mechanically polished to Ra <0.5 µm or electropolished to Ra >0.4 µm.
The tubes are seamless and polished prior to bending. The Pharma-line S U-tubes are bent to a larger radius than required in
ASME BPE. The Pharma-line S is easy to clean and can be steam sterilised. The gaskets are FDA approved and USP class VI.
Main components
5300-0005
A
C
D
D
F
E
G
G
J
K
B
H
A
B
C
D
E
F
G
H
J
NAC plate connection
Fronthead
Tubesheet
Lifting lug
Vent
Flange connection
Leg
Shell
Flange connection
Tube sheet
Tubes are expanded into first sheet, welded and expanded into second sheet. Double tube
sheet minimises the risk of contamination
Shell
Utility media flow on the shell side
Tube bundle
Product flows through a number of tubes which are bundled together
Vent
Vent connection on shell side for venting of air
Drain
Drain connection on shell side for draining
NAC plate connection on
product side
Tri-clamp ferrule to be connected to the heat exchanger by an NAC plate. Tri-clamp ferrules
and gaskets are not supplied
Flange connection on shell side Inlet flange is at the back of the heat exchanger. Outlet flange is placed at the side of the shell
Lifting lug
Legs
To be used when lifting the unit, fixed with bolts and movable, allowing for flexible positioning.