5 Operation
Pay attention to possible faults
Read the instructions carefully
Step 3
DEBRIS INSIDE
Loosen the collar set screw (30), remove the collar (11), and then lift out the
stator (12). Look for and remove any debris caught in the stator and the
vanes of the rotor (32.1). Remove any material wound around the input
shaft (33.1).
32.1
33.1
12
30
11
4125-0005
3
4
In addition, check for any debris caught in the nose of the tee housing (8),
the nozzle housing (9), the nozzles (16), and the outlet holes of the stem
(7). In order to check (7), the cap (6) must be removed and the gear train
assembly pulled up and out of the stem (7) via the rotor (32.1).
8
16
9
7
4125-0006
15
28
22
38
10
6
32.1