5. Maintenance
20
Read the instructions carefully. The items refer to the parts list and service kits section.
5.5
Reassembly
General Notes
All parts must be cleaned thoroughly before reassembling.
Any deposits remaining on the parts can cause difficult
disassembly the next time the Alfa Laval BladeClean needs servicing.
Assemble each O-rings using water for lubrication. This will allow each O-ring to be compressed uniformly in each threaded
joint assembly.
Drawing 1
Start with the upper assembly. Press fit the bearing (5) into the outlet screw (4). Place the gasket (3) at the bottom of (4). Place
the (4) into the Body Tube (1). Place the O-ring (2) into the extension tube (1). Screw the outlet screw (4) in the extension tube
(1).
Drawing 2
Place the seal (8) in the main body (7). Press fit the bearing (5) from the bottom into the main body. Screw the main body
below the extension tube. Place the O-ring (12) on the plunger (11). Insert the plunger (11) through the top of outlet screw (4)
all the way down. Place the spring (14) in position below the main body (7) and screw in the Retainer (12) with (13).
Drawing 1
Make sure the plunger moves smoothly in the body and then place the Bottom Cap (10). Put on the O-ring (6) on the outside of
outlet screw (4). Now the Alfa Laval BladeClean can be attached to the tank adapter (15) with the clamp (16) provided.
This completes the assembly process.