- 11 -
ALFA IN a.s. ©
www.alfain.eu
into the electrode holder, connect the clamps of the ground cable to the welding
piece and you may start welding.
GETTING STARTED TIG
Fig. 3 – Getting started TIG
1. Insert the mains plug into a suitable 3x400 V mains socket, 50-60 Hz. The
supply fuses or circuit breaker should correspond to the technical data
stated in this manual.
2. Switch the main switch
A16
to the position “ON“.
3. Connect the TIG torch to the quick connector (-)
A1
.
4. Connect the earthing cable to the quick connector (+)
A14
.
5. By means of the button
A3
switch to the position TIG
.
6. Connect the gas hose to the gas cylinder connector on the gas bottle.
7. By means of the encoder
A13
set the welding current.