Alfa IN PEGAS 162 E PFC Operating Manual Download Page 9

9/12 

 

ALFA IN a.s. ©   

 

   

 

 

 

 

 

www.alfain.eu

 

 

 

6. GETTING STARTED 

Getting started must be consistent with technical data and conditions of use. 
 
Insert the mains plug into a suitable 1x230 V (or 1 x 110 V) mains socket. The 
supply fuses or circuit breaker should correspond to the technical data in section 
4. Switch the machine on by the ON/OFF switch 

10

. LED 

5

 will illuminate. 

GETTING STARTED MMA – COATED ELECTRODE 

1.  Connect  the  electrode  holder  and  the  work  lead  to  terminals 

8

  and

  9

 

according the instructions on the electrode package

NOTE  Prevent 

touching  the  electrode  any  metal  material  for  in  this  mode  the 
terminals 8 and 9 are under current.   

2.  By means of the switch 

4

 select MMA 

.   

3.  To select the current use potentiometer  

7.

 

4.  Insert the coated electrode into the electrode holder. 

 

GETTING STARTED TIG LIFT ARC 

1.  Fit  the  TIG  Torch  to  the  minus  terminal 

8

  and  fasten  it  by  turning  the 

connector to the right.   

2.  Connect the work lead to positive terminal 

9

 and fasten it by turning the 

connector to the right.  

3.  Connect the work clamp to the work piece or at the welding table. 

4.  By means of the switch 

4

 select TIG 

.   

How

 

to

 connect the gas cylinder 

1.  Ensure that the gas cylinder is secured to a building pillar, wall bracket or 

otherwise securely fixed in an upright position. 

2.  Open the gas valve once to blow out possible dirt particles. 
3.  Connect the gas regulator to the gas cylinder valve. 
4.  Connect the gas hose of the TIG torch to the gas regulator.    
5.  Open the gas cylinder valve, open the valve on the TIG torch and adjust 

the gas flow on the gas regulator. The flow rate will be shown at the flow 
meter. This should be done according the table below. 

 

Summary of Contents for PEGAS 162 E PFC

Page 1: ...ALFA IN a s www alfain eu PEGAS 162 202 E PFC Manual EN 02 WELDING INVERTER PEGAS 162 E PFC PEGAS 202 E PFC OPERATING MANUAL...

Page 2: ...1 INTRODUCTION 3 2 SAFETY INSTRUCTIONS AND WARNINGS 4 3 TECHNICAL DATA 6 4 EQUIPMENT 7 5 OPERATOR CONTROLS 8 6 GETTING STARTED 9 7 ROUTINE MAINTENANCE INSPECTION 10 8 STATEMENT OF WARRANTY 11 9 DISPO...

Page 3: ...l represents the Manufacturer s best judgement the Manufacturer assumes no liability for its use PEGAS 162 E PFC PEGAS 202 E PFC welds by those methods a E MMA coated electrodes up to 4 0 mm b TIG lif...

Page 4: ...rt as possible 12 The operator must wear gloves clothes shoes and a helmet or a welder s helmet which protect and are fire resistant in order to protect him against electric shock flashes and sparks f...

Page 5: ...l standards EN 60974 1 depending on the type of weld current to be used on its waveform and on the hazards arising from the work place These values are not applicable to the strike currents and those...

Page 6: ...PFC Method MMA TIG MMA TIG Mains voltage V Hz 1x110 50 60 1x230 50 60 Welding current range A 10 120 10 120 10 200 10 200 Open circuit voltage U20 V 68 68 Mains protection A 16 25 16 25 Max effective...

Page 7: ...rives to produce the best product possible and therefore reserves the right to change improve or revise the specifications or design of this or any product without prior notice Such updates or changes...

Page 8: ...ROLS Fig 1 Main parts Pos Description 1 LED TIG 2 LED MMA 3 Display set current 4 Method switch MMA electrode TIG 5 LED ON 6 LED over heating 7 Current potentiometer 8 Quick connector 9 Quick connecto...

Page 9: ...rt the coated electrode into the electrode holder GETTING STARTED TIG LIFT ARC 1 Fit the TIG Torch to the minus terminal 8 and fasten it by turning the connector to the right 2 Connect the work lead t...

Page 10: ...ION Do not blow air into the welder during cleaning Blowing air into the welder can cause metal particles to interfere with sensitive electronic components and cause damage to the welder 5 To clean th...

Page 11: ...ervice Department 2 Equipment that has been used beyond the specifications established in the operating manual 3 Installation not in accordance with the installation operating manual 4 Any product tha...

Page 12: ...12 12 ALFA IN a s www alfain eu 10 DECLARATION OF CONFORMITY...