2. SAFETY INSTRUCTIONS AND WARNINGS 

1.  Once  the  packing has  been  opened, make sure  that the  machine  is  not 

damaged. If in any doubt, call the service centre. 

2.  This equipment must only be used by qualified personnel.  
3.  During installation, any electric work must only be carried out by trained 

personnel. 

4.  The machine must be used in a dry place with good ventilation. 
5.  Make  sure  that  no  metal  dust  can  be  drawn  in  by  the  fan  inside  the 

machine, as this could cause damage to the electronic circuits. 

6.  It is prohibited to connect more than one INVERTER generator in series or 

in parallel. 

7.  When installing the machine, follow the local regulations on safety. 
8.  The position of the machine must allow easy access by the operator to the 

controls and connectors. 

9.  When the welding machine is operating, all its covers and doors must be 

closed and well fixed. 

10. 

Do  not  expose  the  welding  machine  to  direct  sunlight  or  to  heavy 

rain. This equipment conforms to protection rating IP23S. 

11. 

During welding, the welding cables must be located near or at ground 

level. They should be as short as possible. 

12. 

The operator must wear gloves, clothes, shoes, and a helmet or a 

welder’s helmet, which protect and are fire-resistant in order to protect him 
against electric shock, flashes and sparks from welding. 

13. 

The  operator  must  protect  his  eyes  with  safety  visor  or  mask 

designed for welding, fitted with standard safety filters. He should also be 
aware  that  during  electrical  welding  ULTRAVIOLET  RADIATION  is 
emitted. Therefore it is vital that his face is also protected from radiation. 
Ultraviolet  rays  produce  the  same  harmful  effect  as  sun  burning  on 
unprotected skin.  

14. 

The operator is obliged to warn anyone near the welding area of the 

risks that welding involves and to arrange to provide adequate protection 
equipment. 

15. 

It  is  very  important  to  arrange  for  sufficient  ventilation,  especially 

when  welding  in  enclosed  spaces.  We  suggest  using  suitable  fume 
extractors to prevent the risk of intoxication by fumes or gas generated by 
the welding process. 

16. 

The operator must ensure all flammable materials are removed from 

the work area to avoid any risk of fire. 

17. 

The  operator  must  NEVER  weld  containers  that  have  previously 

contained petrol, lubricants, gas or similar flammable materials, even if the 
container  has  been  empty  for  a  considerable  time.  THERE  IS  A  VERY 
HIGH RISK OF EXPLOSION. 

Summary of Contents for PEGAS 162 E PFC

Page 1: ...ALFA IN a s www alfain eu PEGAS 162 202 E PFC Manual EN 02 WELDING INVERTER PEGAS 162 E PFC PEGAS 202 E PFC OPERATING MANUAL...

Page 2: ...1 INTRODUCTION 3 2 SAFETY INSTRUCTIONS AND WARNINGS 4 3 TECHNICAL DATA 6 4 EQUIPMENT 7 5 OPERATOR CONTROLS 8 6 GETTING STARTED 9 7 ROUTINE MAINTENANCE INSPECTION 10 8 STATEMENT OF WARRANTY 11 9 DISPO...

Page 3: ...l represents the Manufacturer s best judgement the Manufacturer assumes no liability for its use PEGAS 162 E PFC PEGAS 202 E PFC welds by those methods a E MMA coated electrodes up to 4 0 mm b TIG lif...

Page 4: ...rt as possible 12 The operator must wear gloves clothes shoes and a helmet or a welder s helmet which protect and are fire resistant in order to protect him against electric shock flashes and sparks f...

Page 5: ...l standards EN 60974 1 depending on the type of weld current to be used on its waveform and on the hazards arising from the work place These values are not applicable to the strike currents and those...

Page 6: ...PFC Method MMA TIG MMA TIG Mains voltage V Hz 1x110 50 60 1x230 50 60 Welding current range A 10 120 10 120 10 200 10 200 Open circuit voltage U20 V 68 68 Mains protection A 16 25 16 25 Max effective...

Page 7: ...rives to produce the best product possible and therefore reserves the right to change improve or revise the specifications or design of this or any product without prior notice Such updates or changes...

Page 8: ...ROLS Fig 1 Main parts Pos Description 1 LED TIG 2 LED MMA 3 Display set current 4 Method switch MMA electrode TIG 5 LED ON 6 LED over heating 7 Current potentiometer 8 Quick connector 9 Quick connecto...

Page 9: ...rt the coated electrode into the electrode holder GETTING STARTED TIG LIFT ARC 1 Fit the TIG Torch to the minus terminal 8 and fasten it by turning the connector to the right 2 Connect the work lead t...

Page 10: ...ION Do not blow air into the welder during cleaning Blowing air into the welder can cause metal particles to interfere with sensitive electronic components and cause damage to the welder 5 To clean th...

Page 11: ...ervice Department 2 Equipment that has been used beyond the specifications established in the operating manual 3 Installation not in accordance with the installation operating manual 4 Any product tha...

Page 12: ...12 12 ALFA IN a s www alfain eu 10 DECLARATION OF CONFORMITY...