-9-
ALFA IN a.s. ©
www.alfain.eu
7
GETTING STARTED
Insert the mains plug into a suitable 1x230 V (or 1 x 110 V) mains socket. The
supply fuses or circuit breaker should correspond to the technical data in
section 3. Switch the machine on by the ON/OFF switch (7). LED (1) will
illuminate.
7.1 GETTING STARTED MMA – COATED ELECTRODE
•
Connect the electrode holder and the work lead to terminals (5) and (6)
according the instructions on the electrode package.
NOTE
Prevent touching the electrode any metal material for in this mode the
terminals (5) and (6) are under current.
•
By means of the switch (2) select MMA
.
•
To select the current use potentiometer (3)
•
Insert the coated electrode into the electrode holder.
7.2 GETTING STARTED TIG LIFT ARC
•
Fit the TIG Torch to the minus terminal (5) and fasten it by turning the
connector to the right.
•
Connect the work lead to positive terminal (6) and fasten it by turning the
connector to the right.
•
Connect the work clamp to the work piece or at the welding table.
•
By means of the switch (2) select TIG
.
7.2.1
How
to
connect the gas cylinder
•
Ensure that the gas cylinder is secured to a building pillar, wall bracket or
otherwise securely fixed in an upright position.
•
Open the gas valve once to blow out possible dirt particles.
•
Connect the gas regulator to the gas cylinder valve.
•
Connect the gas hose of the TIG torch to the gas regulator.
•
Open the gas cylinder valve, open the valve on the TIG torch and adjust
the gas flow on the gas regulator. The flow rate will be shown at the flow
meter. This should be done according the table below.