Portable Hand-Operated Pump
SER 8571-5
Alemite LLC
9
Revision (12-09)
26. Make sure Spring Clip (
20
) on the cover is properly
oriented.
27. Install Nuts (
16
), Lock Washers (
15
), and Capscrews
(
5
) that secure the Pump Tube Assembly to the Cover.
• Tighten the Nuts securely.
Attach Material Hoses onto Meter
28. Screw Material Hose (
1
) [with thread sealant] into the
Electronic Meter.
• Tighten the Hose securely.
29. Screw Filter Assembly (
23
) [with thread sealant] onto
the opposite end of the Material Hose.
30. Screw Material Hose (
24
) [with thread sealant] into the
Filter Assembly.
• Tighten the Hose securely.
31. Screw Nozzle Assembly (
22
) onto Material
Hose (
24
) [with thread sealant] as required.
Fluid Filter
NOTE
: Refer to
Figure 4
for component
identification.
32. Install Filter Tube (
40
) into Body (
39
).
33. Install O-Ring (
42
) onto Spring and Adapter
Assembly (
43
).
34. Install the small button of Stud (
41
) into the spring of
the Spring and Adapter Assembly.
35. Screw the Spring and Adapter Assembly into the
Body.
• Tighten the Spring and Adapter Assembly securely.
Priming the Pump
1. Make sure an adequate supply of oil is in the container.
2. Position the Nozzle into a collection container.
3. Cycle the Lever until oil is visible at the Nozzle.
If the pump assembly does not prime, refer to the
Troubleshooting Chart
for details.
4. Continue to cycle the pump until the oil is free of air.
5. Reset the Electronic Meter to zero.