background image

SER 8571-5

Portable Hand-Operated Pump

Revision (12-09)

8

Alemite LLC

Outlet Body

  7. Install and seat Gasket (

34

) into the bottom of Outlet 

Body (

28

).

  8. Install the Rod assembly into the Outlet Body.

  9. Install and seat Gasket (

27

) into the Outlet Body.

10. Install O-Ring (

26

) carefully past the cross-hole on the 

Rod.

11. Screw Packing Nut (

25

) into the Outlet Body.

12. Tighten the Packing Nut securely.

13. Install the Tube assembly over the Rod assembly and 

screw into the Outlet Body.

14. Tighten the Tube securely into the Outlet Body and at 

the same time the Foot Valve Body into the Tube.

Attach Pump Tube to Lever and Cover

15. Screw Knob (

10

) onto Bracket and Lever Assembly 

(

9

).

16. Install Link (

11

) into the Bracket and Lever 

Assembly.

17. Install Screw (

8

) that secures the Bracket and Lever 

Assembly to the Link.

18. Install Nut (

12

) onto the Screw.

• Tighten the Nut securely.

19. Install the Bracket and Lever Assembly and Link onto 

the Pump Tube Assembly.

20. Install Pin (

13

) that secures the Link to the Pump Tube 

Assembly.

21. Install Pin (

7

) that secures the Bracket and Lever 

Assembly to the Pump Tube Assembly.

22. Install Retaining Rings (

6

) onto the end s of both Pins.

23. Screw Nipple (

3

) [with thread sealant on each end] 

into the Outlet Body.
• Tighten the Nipple securely.

24. Screw Electronic Meter (

2

) onto the Nipple.

• See

 Figure 2 

for the proper orientation of the Meter.

• Tighten the Meter securely. 

25. Position the Pump Tube Assembly onto Cover (

14

) as 

illustrated in 

Figure 2

.

Figure 5

Pump Tube Assembly 328255-C4 - Section 

Refer to 

Figure 3 

Parts List

    for Parts Identification

1-800-548-1191-http://[email protected]

Summary of Contents for 8571-5

Page 1: ...ual non drip nozzle assembly electronic meter Pump The low pressure pump included with the assembly is designed to dispense automatic transmission fluid directly from their original 16 gallon containe...

Page 2: ...SER 8571 5 Portable Hand Operated Pump Revision 12 09 2 Alemite LLC Figure 2 Portable Hand Operated Pump Model 8571 Series Exploded View 1 800 548 1191 http www partdeal com info partdeal com...

Page 3: ...Stop 10 32 1 317809 5F 1 13 339961 1 Pin 1 317860 1 24 14 Cover Assembly w Gasket 1 321203 23 15 Washer Lock 1 4 3 324726 9 16 Nut 1 4 20 3 324742 8 17 Screw Thumb 1 4 28 3 324741 11 18 Nut 8 32 1 32...

Page 4: ...SER 8571 5 Portable Hand Operated Pump Revision 12 09 4 Alemite LLC Figure 3 Pump Tube Assembly for Model 8571 Series Exploded View 1 800 548 1191 http www partdeal com info partdeal com...

Page 5: ...ody Plunger 1 172212 14 38 32 O Ring 1 1 4 ID x 1 1 2 OD 1 319320 31 33 Nut Elastic Stop 5 16 18 1 324733 25 34 Gasket 1 324747 30 35 Tube 1 326784 27 36 131315 Valve Foot 1 328254 4 28 37 50712 Body...

Page 6: ...15 and Nuts 16 that secure Pump Tube Assembly 4 to Cover 14 Remove the Pump Tube Assembly from the Cover 3 Unscrew the Electronic Meter from Nipple 3 4 Remove Nozzle Assembly 22 from Material Hose 24...

Page 7: ...lunger Body Clean and Inspect NOTE Use the repair kit for replacement parts Make sure all the components are included in the kit before discarding used parts 1 Clean all metal parts in cleaning solven...

Page 8: ...and Lever Assembly 17 Install Screw 8 that secures the Bracket and Lever Assembly to the Link 18 Install Nut 12 onto the Screw Tighten the Nut securely 19 Install the Bracket and Lever Assembly and Li...

Page 9: ...rial Hose 24 with thread sealant as required Fluid Filter NOTE Refer to Figure 4 for component identification 32 Install Filter Tube 40 into Body 39 33 Install O Ring 42 onto Spring and Adapter Assemb...

Page 10: ...tlet Body 28 1 Tube 35 not sufficiently tight 2 Damaged Gasket 34 1 Tighten Tube 35 into Outlet Body 28 2 Separate Tube 35 from Outlet Body 28 and replace Gasket 34 Internal Leaks Pump does not prime...