background image

Alemite, LLC

167 Roweland Drive, Johnson City, Tennessee 37601

www.alemite.com

Copyright 

© 

2010 by Alemite, LLC

This document contains confidential information that is the property of Alemite, LLC

and is not to be copied, used, or disclosed to others without express written permission.

Service Guide

        3579
393792-6

Electronic Meter

670955

SER 3579

Revision (3-10)

Description

CAUTION

Do not operate this meter with an antifreeze and water mixture. 
Meter will not register properly.

Meter model 3579 is designed to measure a variety of fluids that 

include engine oils, diesel oils and hydraulic oils.

The meter is totally electronic except for the oval gear metering 

mechanism. The electronic register is powered by two 1-1/2 Volt AAA 
alkaline batteries.

The meter can be programmed to register in:

• pints, quarts, or gallons, and totalize in gallons
• liters and totalize in liters

NOTE

: The meter is factory programmed to register in 

quarts and totalize in gallons.

A liquid-crystal display shows the following amounts of fluid 

dispensed by volume:

• Current delivery

RESET

 

TOTAL

 (momentary)

• TOTAL

All three amounts display with a floating decimal point.

• Current delivery (0.000 to 99999)

RESET TOTAL 

and

 TOTAL

 (0.0 to 999999)

The meter’s non-volatile memory retains the unit of measure, totals, 

and calibration factor during battery replacement.

Operation

To zero the current delivery and 

RESET

 

TOTAL

 the meter must be 

in Standby. See 

Figure

 

1

.

Press the 

Reset

 button to zero the current delivery.

When the 

RESET TOTAL

 is required to be reset:

  1. Press the 

Reset

 button.

• The 

RESET TOTAL

 displays for 5 seconds.

  2. Press and hold the 

Reset

 button while the 

RESET TOTAL

 displays.

• The 

RESET TOTAL

 is reset to zero.

The 

RESET TOTAL

 and 

TOTAL

 update automatically during fluid 

delivery.

Figure 1

Electronic Meter Model 3579

Max. Operating 

Pressure

Storage

Temperature

Operating 

Temperature

Accuracy* Repeatability*

Dimensions (w/ Guard)

L x W x H

Weight

psi

bar

° F

° C

° F

° C

in.

cm

lbs

kg

1000

70

-4 to 158

-20 to 70

23 to 122

-5 to 50

± 1%

1%

3.7 x 4.2 x 3.1

9.4 x 10.7 x 7.9 

1.46

0.6

* With SAE 10W Oil at 68° F (20° C)

Table 1

Electronic Meter Model 3579 Specifications

Model

Thread Type

3759-

3/4” NPT

393792-6

3/4” GAS

Programmable Units of Measure

Flow Rate in Units / Min.

Current

Totalizer

Min.

Max.

pint

gallon

1.5 gallons

16 gallons

quart

gallon

liter

liter

6 liters

60 liters

Reviews: