Revision (3-10)

Installation

WARNING

Prior to installation, the following safety 

precautions must be observed. Personal injury can 
occur.

Do not exceed the pressure rating of any component 
in the system.

Protect all fluid and air supply lines from puncture 
or damage. Check all lines for weak or worn condi-
tions prior to use.

Never point a control valve at any portion of your 
body or another person. Accidental discharge of 
pressure and/or material can result in personal 
injury.

Read each step of the instructions carefully. Make 
sure a proper understanding is achieved before pro-
ceeding.

CAUTION

Install a 40-micron or finer filter at the inlet side of 
this meter. Jammed gears, damage to components, 
or inaccurate readings can occur.

Prior to meter installation, flush all contaminants by 

pumping fluid through the system.

Apply thread sealant to all male pipe threads upon 

installation.

Maintenance

WARNING

Release all pressure within the system prior to per-

forming any maintenance procedure.

Repairs should only be performed by a qualified person 
using original repair parts.

Read each step of the instructions carefully. Make sure a 
proper understanding is achieved before proceeding.

Battery Replacement

NOTE

: All meter values remain in memory.

The batteries should be replaced once the battery icon appears on 

the display. See 

Figure 1

IMPORTANT: The meter will no longer register 
should the battery icon begin to flash.

WARNING

Recycle or discard the used batteries properly. Do 

not burn or puncture the batteries. Toxic materials may be 
emitted which can cause personal injury.

CAUTION

Avoid touching the flat surfaces of the new batteries. Skin 
oils can cause battery deterioration. Clean any suspect bat-
tery with alcohol prior to installation.

Install the new Batteries as indicated on the bottom of the meter.

All values remain the same including the Current delivery.

Metering Gear Replacement

IMPORTANT: Install the gear with the magnets (mag-
nets upward) onto the left post of the body as shown 
on Figure 2

Install the additional gear perpendicular to the mag-
net gear. Rotate the gear assembly to ensure the gears 
are properly positioned.