background image

 

21 

Without a properly installed safety reversal system, person (particularly small children) could be SERIOUSLY INJURED 

or KILLED by a closing gate. 

*Too much force on gate will interfere with proper operation of safety reversal system. 

*NEVER increase force beyond minimum amount required to close gate. 

*NEVER use force adjustments to compensate for a binding or sticking gate. 

* If one control (force or travel limits) is adjusted, the other control may also need adjustment. 

* After ANY adjustments are made, the safety reversal system MUST be tested. Gate MUST BE TESTED. Gate MUST 

reverse on contact with a rigid object. 

The  opener  is  equipped  with  an  obstruction  sensing  feature.  If  the  gate  encounters  an  obstruction  the  opener  will 

automatically reverse direction and stop. Based on the length and weight of the gate it may be necessary to make force 

adjustments.  The force  adjustment  should  be  high  enough  that small  objects such as branches or  wind  will not cause 

nuisance interruptions but low enough to prevent serious injury to a person or a vehicle. 

NOTE: 

You may need to increase the stall force in cold weather due to increased resistance from 

gate hinges. The gate opener’s opening/closing force is adjusted automatically according to stall force 

adjustment. 

(Factory set is 3 seconds) 

Press the “FUNC” button to store the data when the close interval is set. The Digital Display will indicate 

“P5”. Now Close Interval Set is finished. 

6.  Adjust the Obstruction Sensitivity/Stall Force 

   

When the Digital Display indicates “P5”, the gate opener is on the Stall Force Adjustment. 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-a Adjust Stall Force of Gate Opener 1   

Now we adjust the stall force of gate 1 

The stall force of gate opener1 is adjusted by pressing “INC” and “DEC” buttons respectively. The Digital 

Display will show “1”-“9” which indicates the stall force levels. “1” means the minimum force, and “9” is 

the maximum force. Each time you press and release the “INC” button, the figure increase by 1, and the 

force  increases  to  a  higher  level.  Each  time  you  press  and  release  the  “DEC”  button,  the  figure 

decreases by 1, and the force decreases to a lower level. Press “FUNC” to store the data. The Digital 

Display will indicate “P6”. Now stall force of gate opener 1 is finished. 

(Factory set is Level 3) 

6-b Adjust Stall Force of Gate Opener 2   

When the Digital Display indicates “P6”.you can adjust force of gate opener 2. 

Please perform the same procedure as gate opener 1 (6-a). 

Press  the  “FUNC”  button to  store  the data  when  stall  force  of gate  opener  2  is  set. Then  “P7”  will be 

shown on the Digital Display. 

 

 

 

 

7. Adjust the Max Motor Running Time (MRT) of the MOTOR for gate opener 

The maximum running time of the MOTOR can be set to make the motor stop running after a specified 

period even if the limit switch is invalid or the clutch is detached. 

7-a. Adjust the MRT of MOTOR1 

When the Digital Display indicates “P7”, you can adjust the 

MRT

 of MOTOR1. 

The 

MRT

 of MOTOR1 is adjusted by pressing “INC” and “DEC” buttons respectively. The Digital Display 

will show “01”-“50” which indicates the 

MRT

 of MOTOR1 from 1 to 50 seconds. 

You can hold pressing the “INC” or “DEC” button for more than 1 second to speed up the setting. Press 

the “FUNC” button to store the data when you finish setting. The Digital Display will indicate “P8”. 

(Factory default setting is “40” seconds) 

Summary of Contents for AS 1300

Page 1: ...REV 13c www WholesaleGateOpener com...

Page 2: ...ng Hardware 10 13 Installing the Mounting Hardware 13 14 Installing the Opener 14 Mounting the Control Box 15 16 Connecting of the control board 17 19 How to learn or erase the remote 19 Setting of th...

Page 3: ...gate and adjacent structure when opening and closing to reduce the risk of entrapment Swinging gates shall not open into public access areas 7 The opener is intended for use only on gates used for veh...

Page 4: ...ener is provided with two safety warning placards The placards are to be installed on the front and back of the gate where they are plainly visible The placards may be mounted using cable ties through...

Page 5: ...4 REV 13a Dual Gate Opener Parts List Opener and Mounting Hardware...

Page 6: ...5 REV 13c Single Gate Opener Parts List Opener and Mounting Hardware...

Page 7: ...rts List Tools Needed Power Drill Tape Measure Open End Wrenches 14 17 or Adjustable Wrenches Wire Strippers C Clamps small medium and large Level Hacksaw or Heavy Duty Bolt Cutters Phillips Screwdriv...

Page 8: ...Temperature 20 50 4 F to 122 F Protection class IP44 Features Soft start and soft stop Emergency release key in case of power failure Dual Single gate running mode Adjustable opening closing interval...

Page 9: ...8...

Page 10: ...ual Gate Overview Pull to Open Gates Important The second gate opener cable should be put into the PVC conduit not provided which is buried underground This protects the cable from lawn mowers and str...

Page 11: ...bolts long enough to pass through the entire post When mounting the post brackets to wooden posts a larger size washer or metal plate should be used between the bolts and the wooden post to ensure th...

Page 12: ...ot bracket as shown Place a 10 washer 10 lock washer and M10 nut on the bottom of the bolt and hand tighten NOTE Pay attention to the distance A when installing the opener It MUST be longer than or at...

Page 13: ...post and the gate Position the gate bracket and the post bracket assembly so that the gate opener is level with the horizontal cross member of the gate While holding the opener in the desired level p...

Page 14: ...ckets do not bind in the gate open and gate closed positions If you don t have enough distance or the gate opener is binding on the post pivot bracket you may move the post pivot bracket assembly slig...

Page 15: ...clevis pins with the two hairpin clips Step 6 Using a drill and a bit of 10 5 drill holes through the post and the gate at the sign bolt hole point Step 7 Attach the post bracket assemblies to the gat...

Page 16: ...control box use the deck screws not provided Ensure the control box is installed in a secure surface and at least 100 cm 40 inches above the ground to protect it from rain snow etc which probably caus...

Page 17: ...ables 1 5m length are provided Other cables are subject to site installation requirement and not provided CAUTION Make sure the cable outlet hole in the Control Box is always down during installation...

Page 18: ...17 REV 13c Connecting of the control board...

Page 19: ...WA4004 to connect Battery with battery s Terminal of control board if the battery is used as the primary power supply in system such as SOL PLUS KIT Please refer to the user manual of control LM118 W...

Page 20: ...uld be connected into the 20 terminal The RED wire of the external receiver should be connected into the 9 terminal Wired Keypad 24VDC optional The RED wire of the wired keypad should be connected int...

Page 21: ...ve Gate When the Digital Display indicates P3 the gate opener is on the Open Interval between Master Slave Gate Setting The open interval can be adjusted by pressing the INC and DEC Buttons respective...

Page 22: ...is on the Stall Force Adjustment 6 a Adjust Stall Force of Gate Opener 1 Now we adjust the stall force of gate 1 The stall force of gate opener1 is adjusted by pressing INC and DEC buttons respective...

Page 23: ...ases by 1 and the timing decreases by 1 second When the timing is 00 the automatic closing function is shut off and the gate will stay open Factory set is 60 seconds Press the FUNC button to store the...

Page 24: ...is not running the Digital Display indicates When Gate Opener 2 is set as Master gate i e when 10 indicated at P2 set mode in the Control Board the Digital Display flashes n before the gate completel...

Page 25: ...gate will stop at its programmed closing position The gate will reverse in case of obstruction or stall force during closing and it will move to the programmed opening position Emergency Release Insta...

Page 26: ...wo C clamps Step 10 The motors power wires and limit wires connection by Push to Open is different from the connection by Pull to Open So motor 1 and motor 2 wires should be connected to the control b...

Page 27: ...color coded Make sure the AC input is connected Check if the fuse in control board is bad 2 Opener powers up but does not run Arm cable loose or disconnected Verify that all of the wires going to the...

Page 28: ...ot shorted Ensure that the motor cable is away from sources of electrical interference such as electric fences power lines etc 6 Gate opens closes or stops on its own Ensure that the key for manual re...

Page 29: ...28 Quick Setting Guide...

Page 30: ...29...

Page 31: ...30...

Page 32: ...31...

Page 33: ...32...

Page 34: ...www WholesaleGateOpener com 7106 S 220th St Kent WA 98032 USA sales WholesaleGateOpener com 2013 2015 ALEKO All Rights Reserved...

Reviews: