1100W Garden Pump
AFTER SALES SUPPORT
e-mail: [email protected]
1800 909 909
MODEL: №.
XKJ-1109PE • 1/2016 • 44268
(toll free)
18
AFTER SALES SUPPORT
(toll free)
1100W Garden Pump
e-mail: [email protected]
1800 909 909
MODEL: №.
XKJ-1109PE • 1/2016 • 44268
Troubleshooting
Problem
Possible Cause
Solution
Motor fails to start up • No mains voltage
• Pump rotor blocked -
thermostat switched off
• Check voltage
• Dismantle and clean pump
No intake
• Intake pressure line not in water
• Pump chamber without water
connection
• Air in intake line air-tight
• Intake valve leaks
• Strainer (intake valve) blocked
• Max. suction height exeeded
• Insert pressure line in water
• Remove the coarse filter with the non-return
valve, then fill water into the pump housing.
• Make sure intake line is close
• Clean intake valve
• Clean strainer
• Check suction height
Inadequate
delivery rate
• Suction height too high
• Coarse filter dirty
• Water level falling rapidly
• Pump performance diminished by
contaminants part
• Check suction height
• Change to “Clean filter”
• Place the suction hose at a deeper level
• Clean pump and replace wearing
Thermostat switches
pump off
• Motor overloaded - friction caused by
foreign substances too high
• Dismantle and clean pump
Prevent intake of foreign substances (filter)