1100W Garden Pump
AFTER SALES SUPPORT
e-mail: [email protected]
1800 909 909
MODEL: №.
XKJ-1109PE • 1/2016 • 44268
(toll free)
14
AFTER SALES SUPPORT
(toll free)
1100W Garden Pump
e-mail: [email protected]
1800 909 909
MODEL: №.
XKJ-1109PE • 1/2016 • 44268
Cleaning the Coarse Filter Insert
Remove the water filler cap (1) using the large plastic spanner (8) provided.
Remove the coarse filter (2) and the non-return valve (3) by lifting the filter.
The non-return valve (3) is clipped onto the coarse filter (2). The assembly
should remove as shown in the Fig F. If the coarse filter (2) and non-return
valve (3) does not lift out of the pump, remove the
water intake screw (7) and gently push the coarse
filter (2) outward using a flat shaped pusher of
approx 20mm diameter (Fig D).
Ensure there are no blockages in the filter.
Once any blockages are cleared return the filter
assembly back into the unit.
Replacing the Mains Cable
WARNING: If the mains cable is damaged, IMMEDIATELY turn OFF the
power supply and remove the 220 - 240V plug from the socket.
If the supply cord is damaged, it must be replaced by an electrician with a
special cord or assembly available from the manufacturer or service agent.
F.