Fitting a suction pipe
• Screw an intake hose* (min. 19 mm (3 1/4”)) plastic hose with spiral
reinforcement) either directly or with a threaded nipple to the pump’s
intake port (6) (33.3 mm (R1) (1in BSP)) (see Fig. A).
• The intake hose* should rise from the water pick-up point to the pump.
Always avoid laying the intake line higher than the pump. Air bubbles in
the intake line delay and hinder suction.
• The intake and pressure lines* must be attached
in such a way that they do not place the pump
under any mechanical strain.
• The intake valve should be immersed in the
water that the pump cannot run dry even if the
water level falls.
• If the intake line* is not air-tight the intake of air
will hinder the intake of water.
Pressure line connection
IMPORTANT. ONLY use either of the two outlet adaptors ((10) and (11))
supplied with the pump. DO NOT purchase any other fitting and attempt
to screw directly into the pump. Other purchased filtings can ONLY be
screwed directly into the THREADED adaptor (11) provided.
• The pressure line* (should be at least 19mm (3/4”)) must be connected
to the pump’s pressure outlet (5) either directly or via a threaded nipple
using the supplied adaptors only.
The straight hose adaptor (10) will accept a 19mm hose*. The threaded
adaptor will accept pipe fittings* with a 3/4” BSP (20 mm) thread, either
for hard plumbing or hose applications.
• A 13 mm (1/2”) pressure hose* can also be used with the appropriate
screw connections, but this will only reduce the delivery rate.
• All shut-off devices (spray nozzles, valves etc.) in the pressure line must be
fully opened when priming so that any air in the intake line can escape.
* Not supplied with the product.
A.