between exchange and defrost. To activate Comfort Defrost, position a jumper on
the configuration port 5 and make sure it connects boths pins in the row.
»
Note that the Extended and Comfort Defrost settings can not be activated at
the same time.
This means there should never be jumpers on both configuration
ports 5 and 6.
5b) Slave mode
»
In slave mode, an external device (e.g. air handler) or switch will determine when
the HRV/ERV will operate.
»
By default, the slave mode option is DISABLED.
»
To activate slave mode, position a jumper on the configuration port 7 and make
sure it connects boths pins in the row.
6. Once confguration is complete, replace the circuit board cover and the terminal block
and proceed to wiring the unit to the controls.
Unit Wiring
A) Unit wiring to accessories
All units can be used with the following Aldes wall accessories:
611227: Electronic Humidistat with liquid crystal display
611229: Speed Control
611230: Mode Control
611242-FC: Digital Multifunction Wall Control
These can all be used on their own or with a
timer (611228). To wire an accessory and/or
a timer, connect the HRV/ERV as illustrated
on the right.
8 7 6
2
1
3
4
5
611227
611229
611230
611242
611228
Accessories
Timer
NO COM NC
Fan interlock
FICHE DE POSITIONNEMENT DES JUMPERS - RÉSIDENTIEL
FICHE DE POSITIONNEMENT DES JUMPERS RÉSIDENTIEL - JUIN 2019 - V1.0
ALD-VRC-RES : 699039 - 699040 - 699041 - 699042
Dégivrage confort
7 6 5 4 3 2 1
FICHE DE POSITIONNEMENT DES JUMPERS - RÉSIDENTIEL
FICHE DE POSITIONNEMENT DES JUMPERS RÉSIDENTIEL - JUIN 2019 - V1.0
ALD-VRC-RES : 699039 - 699040 - 699041 - 699042
Mode relais
7 6 5 4 3 2 1