OmniSwitch Backup Power Shelf/System (BPS)
Rack-Mounting
OmniSwitch Backup Power Shelf/System (BPS)
January 2013
page 4-11
Mid-Mounting the Chassis In the Rack
The chassis may also be installed in the rack using mid-mount flanges. To mid-mount the chassis in a
rack, follow the steps below.
1
If applicable, remove the factory-installed front mounting plate and slot rails from the side of the
chassis by loosening and removing the attachment screws.
2
Install the individual mounting brackets at the midpoint of the chassis using the four threaded holes on
each side.
3
Mark the holes on the rack where the chassis is to be installed.
4
One person should lift and position the chassis until the mid-mount flanges are flush with the rack post.
5
Align the holes in the flanges with the rack holes marked in step 3.
Remove