Type
Message
Location
Additional Information
Action
175
NMC WAIT ACK TIMEOUT
The PCX received no acknow-
ledgement for the establishment
request sent to the NMC
CPU (80)
176
NMC PHONE NB MISSING
The PCX attempted to call the
NMC to send urgent alarms, but
the NMC number was not spe-
cified
CPU (80)
177
ADDRESS NOT REGISTERED
The PCX attempted to call the
NMC, but the NMC refused the
call because it didn't recognize
the PCX
CPU (80)
178
UNEXPECTED ALARM
Unsuccessful anomaly transla-
tion for the NMC
CPU (80)
190
UNKNOWN IPUI
A GAP handset tried to access
the PBK without being re-
gistered
CPU (80)
INFO 0, INFO 1, INFO 2, INFO 3 =
corresponding byte of port identifier
221
ETHERNET DOWN
Ethernet interface of the IP-LAN
board is down.
Board loca-
tion.
Ethernet in-
terface
marker.
Check the
LAN connec-
tion and, if ne-
cessary, the
LAN elements
(hub, switch).
222
ETHERNET UP
Ethernet interface of the IP-LAN
board is working.
Board loca-
tion.
Ethernet in-
terface
marker.
223
REMOTE GATEWAY DOWN
Remote gateway is out of ser-
vice.
INFO 0 to INFO 3: bytes corres-
ponding to the IP address Network
format
Check the IP
connectivity to
the remote
gateway
(LAN, inter-
mediate IP
router) and
the remote
gateway
status.
224
REMOTE GATEWAY UP
Remote gateway is working
INFO 0 to INFO 3: bytes corres-
ponding to the IP address Network
format
Chapter