Type
Message
Location
Additional Information
Action
124
FAN STATUS
CPU (80) or
Controller
Board (81)
or (82)
INFO 0 = fan identity (0 = fan 1; 1 =
fan 2)
INFO 1 = fan status (True = OK;
False = KO)
125
POWER SAVING
System in power-saving mode;
only the 2 first Reflexes tele-
phones as well as all T0 ac-
cesses will be taken into ac-
count
INFO 0 = module (0 = basic mod-
ule; 1 = extension 1; 2 = extension
2)
INFO 1 = reason (0 = Fan problem)
Check rota-
tion of the
module fans.
126
DSP RESOURCE KO
Message not processed by the
DSP of one of the controller
boards
Controller
board (81
or 82)
INFO 0 = DSP type 0 or 1 (DSP0 or
DSP1)
127
DSP RESULT CODES
These codes are used in con-
firmation messages and by the
reception buffer
Controller
board (81
or 82)
INFO 0 = DSP type 0 or 1 (DSP0 or
DSP1)
INFO 1 = Result code
INFO 2 = Result sub-code
INFO 3 = Type of resource
128
DSP KO
The DSP of one of the controller
boards is out of service.
CPU (80) or
controller
board (81
or 82)
INFO 0 = 0 or 1 (DSP0 or DSP1)
129
CPU KO
PowerCPU EE board not detec-
ted by the backpanel board 10
minutes after initialization
INFO 0 = type of CPU (0 = Internet
access; 1 = VoIP)
INFO 1 = number of CPU resets
during the-10 minute period
INFO 2 = CPU state
INFO 3 = last byte of MAC
(Ethernet) Internet address of CPU
140
UNREGISTRATION
SIP un-registration
CPU (80)
INFO 0 = octet 1 of the IP address
of the remote registry
INFO 1 = octet 2 of the IP address
of the remote registry
INFO 2 = octet 3 of the IP address
of the remote registry
INFO 3 = octet 4 of the IP address
of the remote registry
141
REGISTER OK
SIP registration success
CPU (80)
INFO 0 = octet 1 of the IP address
of the remote registry
INFO 1 = octet 2 of the IP address
of the remote registry
INFO 2 = octet 3 of the IP address
of the remote registry
INFO 3 = octet 4 of the IP address
of the remote registry
Chapter
6
% *
36/62
! "#$ ! % $& !
Summary of Contents for OmniPCX Office