10
OAW-AP228 Wireless Access Point
| Installation Guide
Figure 9
Installing a Cable Gland
1. Slide the sealing nut over the cable (without the RJ45 connector attached to the end).
2. Slide the clamping ring over the cable.
3. Using a crimping tool, attach the shielded RJ45 connector to the end of the cable.
4. Remove the weatherproof cap on the Ethernet port.
5. Insert the RJ45 connector to the Ethernet port.
6. Screw the clamping ring onto the Ethernet port.
7. Screw the sealing nut onto the clamping ring.
Verifying Post-Installation Connectivity
The integrated LEDs on the AP can be used to verify that the AP is receiving power and initializing
successfully (see
Table 1
and
Table 2
). Refer to the
AOS-W Quick Start Guide
for further details on
verifying post-installation network connectivity.
Configuring the AP
AP Provisioning/Reprovisioning
Provisioning parameters are unique to each AP. These local AP parameters are initially configured on
the switch which are then pushed out to the AP and stored on the AP itself. Alcatel-Lucent
recommends that provisioning settings be configured via the AOS-W Web UI only. Refer to the
AOS-W
User Guide
for complete details.
AP Configuration
Configuration parameters are network or switch specific and are configured and stored on the
switch. Network configuration settings are pushed out to the AP(s) but remain stored on the switch.
Configuration settings can be configured via the AOS-W Web UI or AOS-W CLI. Refer to the
AOS-W
User Guide
for complete details.
The cable is not included and must be purchased separately. Purchase a suitable UV-resistant, outdoor rated,
CAT 5E or better RJ45 cable for use with the AP.
Sealing Nut
Clamping Ring
CAT 5E or Better Cable
Seals
The seals inside the clamping ring by factory default is applicable for cables with 5-8.5 mm diameter. In the
cable gland kit, another seals is provided for use with the cables with 7-10 mm diameter.