Alcad GRF-003 Manual Download Page 8

The product herewith complies with the requirements of the Low Voltage Directive

73/23/ECC    and  the  EMC  Directive  89/336/EEC  and  their  relevant  amendments,  gathered  under  the  directives  93/68/EEC.

Supplementary Information:

to comply with these directives, do not use the products without covers and operate the system as specified.

Note:

TEL-001, TUN-001, TES-001, GRF-001, GRF-003, GRF-004, GRF-005, ALA-040, ALA-020,

ABR-001, ABR-002, ABR-003, ABR-004

Manufacturer's Name:

ALCAD, S.A.

Manufacturer's Address:

Polígono Industrial de Ventas

C/Gabiria, 15 - Apdo. 455

20305 IRUN

 (Guipúzcoa)

SPAIN

declares that the product

96 & 97 Series: DOOR ENTRY SYSTEMS

Product Name:

Model Number(s):

INCLUDING ALL OPTIONS

Product Option(s):

EN60065
EN 50081-1 Generic Emission Standard

EN 50082-1 Generic Inmunity Standard

is in conformity with:

Safety:

DECLARATION OF CONFORMITY

according to  EN 45014

Antton Galarza / General Manager

Irún,

Date

18-01-01

EMC:

PORTERO  ELECTRÓNICO  - 

DOOR  ENTRY  SYSTEMS

  -  INTERPHONE  ÉLECTRONIQUE

Tel. 080 38 - 91 73

Fax 080 38 - 91 74

HOLZHAUSEN, 11

83556 GRIESSTATT

 - Deutschland

Tel. 00 34 - 943 63 96 60

Fax 00 34 - 943 63 92 66

B.P. 284

64702 HENDAYE

 - France

Tel.  21 - 716 10 36

Fax  21 - 716 41 09

R. Dr. JOAQUIM MANSO, 12A

1500 LISBOA

 - Portugal

ALCAD, S.A.

Tel. 943 63 96 60

Fax 943 63 92 66

Int. Tel. +34 - 943 63 96 60

[email protected]

Apdo. 455 - C/GABIRIA, 15

20305 IRUN

 - Spain

Cod. 26178 - Rev

. 01

Summary of Contents for GRF-003

Page 1: ...onsists of a microprocessor loudspeaker microphone amplifier volume control on the panel and telephone door opener relay light switch for the panel and red indicator showing that the panel is not auth...

Page 2: ...25 mm2 230V 230V Llamada Call Appel Llamada Call Appel Llamada Call Appel 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Llamada Call Appel Llamada Call Appel TEL 001 J1 9 1 2 3 4 7 10 11 1213 14 15 16 17 1...

Page 3: ...onic call 9 Panel lighting 10 Panel lighting 11 Door opener 12 Door opener 16 Multiple access urbanization 17 Multiple access 18 Multiple access common J1 Main panel selection Masse d alimentation V T...

Page 4: ...s t l phones Com n de los tel fonos Telephone common terminal Fil commun des t l phones Micr fono de los tel fonos Telephone microphone Micro des t l phones Altavoz de los tel fonos Telephone loudspea...

Page 5: ...upo f nico hacia el tel fono Si no detecta el fallo el tel fono puede estar averiado Se oye un pitido en la placa El sonido se acopla Baje el volumen del sonido mediante los reguladores de volumen del...

Page 6: ...a telephone from the entrance panel Check connections 2 and 3 from the audio unit to the telephone If you cannot find the fault there may be something wrong with the telephone You cannot hear a entran...

Page 7: ...et le t l phone concern Si vous n observez pas d anomalie il se peut que le t l phone soit en d faillant La plaque met un sifflement Le son est accoupl R duisez le volume du son au moyen des syst mes...

Page 8: ...declares that the product 96 97 Series DOOR ENTRY SYSTEMS Product Name Model Number s INCLUDING ALL OPTIONS Product Option s EN60065 EN 50081 1 Generic Emission Standard EN 50082 1 Generic Inmunity St...