Alcad GRF-003 Manual Download Page 6

OPERATING PROBLEMS

If there is a fault, connect up a single telephone to terminals
1, 2, 3, 4 and to a push button on the entrance panel where
the anomaly is. In this way, you will be able to check whether
the  problem  is  in  the  entrance  panel  or  in  the  telephone
connections.

Nothing works.

Check the mains voltage in the power supply. Check that
the voltage between   and 

V  

of the power supply is 12

Vac. Check whether there are any short circuits and fix
them. Disconnect the power supply for 1 minute and then
connect it up again.
If it still doesn’t work, disconnect all the power supply 

V

and   terminals, and check that the voltage between 
and 

V

 is 12 Vac, if this is not the case then there may

be something wrong with the power supply.

The card holders do not light up.

Check that the voltage between   and 

V

 of the power

supply is 12 Vac. Check that the voltage between 9 and
10 in the audio unit, with the lighting push button activated,
is 12 Vac. Check whether the lamp is burnt out.

The lighting push button pilot does not light up.

Check that the voltage between   and 

V

 in the audio

unit is 12 Vac. If the voltage is correct, there may be
something wrong with the audio unit.

You cannot hear any telephones from the entrance
panel.

Check connections 2 and 3 from the audio unit to all the
telephones. Check the volume control on the panel and
the lighting push button pilot. Make certain that connectors
17 and 18 on the panels are connected up (Multiple-
access installations). If you cannot find the fault, there may
be something wrong with the audio unit.

You  cannot  hear  a  telephone  from  the  entrance
panel.

Check connections 2 and 3 from the audio unit to the
telephone. If you cannot find the fault, there may be
something wrong with the telephone.

You cannot hear an entrance panel on any telephone.

Check connections 2 and 4 from the audio unit to all the
telephones. Check the volume control on the telephones
(on the panel) and the lighting push button pilot. If you
cannot find the fault, there may be something wrong with
the audio unit.

You cannot hear the entrance panel on a telephone.

Check connections 2 and 4 from the audio unit to the
telephone. If you cannot find the fault, there may be
something wrong with the telephone.

The lighting push button pilot does not light up.

Check that the voltage between the mass and Vac in the
audio unit is 12 Vac. If the voltage is correct, there may
be something wrong with the phonic unit.

You cannot hear any telephones from the entrance
panel.

Check connections 2 and 3 from the phonic unit to all the
telephones. Check the volume control on the panel and
the lighting push button pilot. If you cannot find the fault,
there  may  be  something  wrong  with  the  audio  unit.

You  cannot  hear  a  telephone  from  the  entrance
panel.

Check connections 2 and 3 from the audio unit to the

telephone. If you cannot find the fault, there may be
something wrong with the telephone.

You cannot hear a entrance panel on any telephone.

Check connections 2 and 4 from the audio unit to all the
telephones. Check the volume control on the telephones
(on the panel) and the lighting push button pilot. If you
cannot find the fault, there may be something wrong with
the audio unit.

You cannot hear the entrance panel on a telephone.

Check connections 2 and 4 from the audio unit to the
telephone. If you cannot find the fault, there may be
something wrong with the telephone.

You  can  hear  whistling  in  the  panel.  The  sound
produces feedback.

Lower the sound level using the volume control on the
audio unit.

The call tone doesn’t ring on any telephone.

Check that the voltage between 2 and 7 in the audio unit,
without pressing the push button, is 9 Vdc. Check the
connection between 7 in the audio unit and the push
buttons. Check connection 2 from the audio unit to the
telephones. If you cannot find the fault, there may be
something wrong with the audio unit.

The call tone doesn’t ring in a telephone.

Check connections 2 and 5 from the telephone to the
entrance panel. Check that the telephone is not off the
hook. Check the push-button connection on the entrance
panel. If you cannot find the fault, there may be something
wrong with telephone or the panel push-button.

You cannot hear the call confirmation on the entrance
panel.

Check that you can hear the telephones on the entrance
panel. Check that the call tone rings on the telephones.
If you cannot find the fault, there may be something wrong
with the audio unit.

The door-opener doesn’t work.

Check that the voltage between 1 and 2 in the audio unit,

without pressing the door-openers, is 5 Vdc. Check that
the voltage between 11 and 12 in the audio unit, when
you press the door-openers, is 12 Vac. If you cannot find
the fault, the lock may be broken.

The  door-opener  doesn't  work  unless  someone
presses a push button

Check that at least one entrance panel has been defined
as  the main one. If you cannot find the fault, there may
be something wrong with the audio unit.

You can hear several entrance panels at the same
time on the telephones.

Check that only one panel has been defined as the main
one. Make certain that connectors 17 and 18 on the
panels are connected up. If you cannot find the fault, there
may be something wrong with the audio unit.

When  you  call  one  of  the  panels  the  rest  of  the
panels in the system are not deactivated.

Make certain that connectors 17 and 18 on the panels
are connected up. Check that the voltage between 2 and
17 in each one of the audio unit is 8 Vdc when you press
the push button on one of the panels. If you cannot find
the fault, there may be something wrong with the audio
units.

PORTERO  ELECTRÓNICO  - 

DOOR  ENTRY  SYSTEMS

  -  INTERPHONE  ÉLECTRONIQUE

Summary of Contents for GRF-003

Page 1: ...onsists of a microprocessor loudspeaker microphone amplifier volume control on the panel and telephone door opener relay light switch for the panel and red indicator showing that the panel is not auth...

Page 2: ...25 mm2 230V 230V Llamada Call Appel Llamada Call Appel Llamada Call Appel 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Llamada Call Appel Llamada Call Appel TEL 001 J1 9 1 2 3 4 7 10 11 1213 14 15 16 17 1...

Page 3: ...onic call 9 Panel lighting 10 Panel lighting 11 Door opener 12 Door opener 16 Multiple access urbanization 17 Multiple access 18 Multiple access common J1 Main panel selection Masse d alimentation V T...

Page 4: ...s t l phones Com n de los tel fonos Telephone common terminal Fil commun des t l phones Micr fono de los tel fonos Telephone microphone Micro des t l phones Altavoz de los tel fonos Telephone loudspea...

Page 5: ...upo f nico hacia el tel fono Si no detecta el fallo el tel fono puede estar averiado Se oye un pitido en la placa El sonido se acopla Baje el volumen del sonido mediante los reguladores de volumen del...

Page 6: ...a telephone from the entrance panel Check connections 2 and 3 from the audio unit to the telephone If you cannot find the fault there may be something wrong with the telephone You cannot hear a entran...

Page 7: ...et le t l phone concern Si vous n observez pas d anomalie il se peut que le t l phone soit en d faillant La plaque met un sifflement Le son est accoupl R duisez le volume du son au moyen des syst mes...

Page 8: ...declares that the product 96 97 Series DOOR ENTRY SYSTEMS Product Name Model Number s INCLUDING ALL OPTIONS Product Option s EN60065 EN 50081 1 Generic Emission Standard EN 50082 1 Generic Inmunity St...

Reviews: