background image

Salt electrolysis Hidrolife  / 

 

5

Electronic box

6.

Electrolysis cell

7.

Description

SAL 16

Electrolysis cell

4 Titanium cell plates MONOPOLAR

Minimum flow

5 m

3

/h

Dimension cell plates

200 x 45 mm

Material cell housing

Plastic PVC transparent

Cell fastener

Thread for an easy installation

Diameter tube connection

63 mm

Dimension cell

355 x 305 x 305 mm

Cell cable size

(3 x 4) x 1,5 m

Gas sensor

Incorporated in the cell

Maximum pressure

4 kg/cm

2

Maximum temperature

45°C

Description

SAL 16

Max. production Cl

2

/h

16 g

Salt concentration

From 3 gr to 100 gr Na/Cl

m

3

  Pool (to 28ºC)

65 m

3

m

3

  Pool (+28ºC)

40 m

3

Display

2,8’’ TFT mobile (20 m) color display (5 languages)

Power supply

220 V 50/60 Hz

Outlet

8-15 A

Maximum consumption

120 W

Dimensions

270 x 220 x 115 mm

Electronic box

Fireproof plastic ABS black

Front cover

Plastic ABS yellow

Electronic

Microprocessor 32 bit

Intensity control

Volt

Ventilation

Fan

Automatic cleaning

Programmable from 1 to 24 hours

Flow switch

Gas sensor

Hour counter

Yes - accessible by client

Control production of disinfection

g/l

Alarms

Insufficient salt / no flow / pH metering / pH extremely high or low / pH max. metering time / memory error

Display salt concentration

Detects gr salt / l (precision ± 10%)

Production control by pool cover

Programmable 0-100% production of disinfection depending on pool cover open or closed

Production control by ext. signal

Programmable 0-100% production of disinfection depending on external signal (2nd analog. inlet)

Communication

MODBUS / WIFI

Control main outputs

Filtration time / light / temperature

Control additional outputs

4 relays for the control of 4 additional machines for the pool

Life time  

guaranteed

Self-cleaning

TOTAL 

POOL 

CONTROL

TOTAL 

POOL 

CONTROL

SELF

CLEAN

Programmable  

polarity change

Transparent  
PVC holder

Security  

sensor

SAFETY

SENSOR

Cells for all  

pool sizes

250

gr/h

8000 H

Filtration  

pump control

Complete 

pool control

TOTAL 

POOL 

CONTROL

TOTAL 

POOL 

CONTROL

TOTAL 

POOL 

CONTROL

Light control

Control of 4  

additional 
machines

Temperature  

control

°C

PH- 

management

pH

REDOX- 

management

rH

Free chlorine  

management

CI

2

+4

Summary of Contents for HIDROLIFE

Page 1: ...11 02 2020 REVIZE 11 02 2020 EN Salt electrolysis HIDROLIFE from 3g salt l Portable color display TFT Upgrade possible Worldwide remote control Self clean WIFI and MODBUS Sea water INSTALLATION AND USER GUIDE ...

Page 2: ...eatment system and a controller for swimming pools Water treatment The salt water electrolysis produces chlorine from a base of salt water of low salinity The electrolysis cell attains a production of sodium hypochlorite liquid chlorine from 3g salt per liter The chlorine combats and eliminates bacteria virus pathogenic agents and oxidizes organic matter present in the water The used sodium hypoch...

Page 3: ...ol water Let the circulation pump run during the first 24 hours The system may operate while the salt is dissolving and will operate without problems with salt concentrations from 2 5 g l to 50 g l In pools with strong insolation it s necessary to add 40 gr m3 of stabiliser isocyanuric acid General maintenance 1 The pool must be vacuumed as usual and the skimmers emptied whenever necessary 2 FILTE...

Page 4: ...cell is guaranteed for 5 000 hours approx 2 3 years of summer usage Free chlorine levels don t reach 0 8 ppm Increase filtration interval Increase electrolysis level Check levels of sodium bromide or common salt in the pool 6 gr NaCl l Check level of isocyanuric acid in pool 30 50 ppm only if using common salt Check if reactive agents in test kit are expired Check if the temperature or amount of u...

Page 5: ...m 1 to 24 hours Flow switch Gas sensor Hour counter Yes accessible by client Control production of disinfection g l Alarms Insufficient salt no flow pH metering pH extremely high or low pH max metering time memory error Display salt concentration Detects gr salt l precision 10 Production control by pool cover Programmable 0 100 production of disinfection depending on pool cover open or closed Prod...

Page 6: ...erometric Au Cu Glass Thermometer Measuring range 0 14 pH 0 1000 mV 0 10 ppm 0 20 000 MS 0 100 C Measuring precision 0 1 pH 1 3 mV 0 10 ppm 10 MS 100 MS 1 C Material Ag Cl Gold Copper gold Stainless steel Probe holder ABS 50 63mm Supplementary equipment Includes 2 m of flexible tube valve Cable 2 m Plug BNC with protection BNC with protection Connectors Connectors Connectors ...

Page 7: ...Salt electrolysis Hidrolife 7 Notes ...

Page 8: ...Thank you for using ALBIXON products ALBIXON export albixon com www ALBIXON com Note that the photos used in the manual are illustrative only Printing and typesetting errors reserved ...

Reviews: