Salt electrolysis Hidrolife /
5
Electronic box
6.
Electrolysis cell
7.
Description
SAL 16
Electrolysis cell
4 Titanium cell plates MONOPOLAR
Minimum flow
5 m
3
/h
Dimension cell plates
200 x 45 mm
Material cell housing
Plastic PVC transparent
Cell fastener
Thread for an easy installation
Diameter tube connection
63 mm
Dimension cell
355 x 305 x 305 mm
Cell cable size
(3 x 4) x 1,5 m
Gas sensor
Incorporated in the cell
Maximum pressure
4 kg/cm
2
Maximum temperature
45°C
Description
SAL 16
Max. production Cl
2
/h
16 g
Salt concentration
From 3 gr to 100 gr Na/Cl
m
3
Pool (to 28ºC)
65 m
3
m
3
Pool (+28ºC)
40 m
3
Display
2,8’’ TFT mobile (20 m) color display (5 languages)
Power supply
220 V 50/60 Hz
Outlet
8-15 A
Maximum consumption
120 W
Dimensions
270 x 220 x 115 mm
Electronic box
Fireproof plastic ABS black
Front cover
Plastic ABS yellow
Electronic
Microprocessor 32 bit
Intensity control
Volt
Ventilation
Fan
Automatic cleaning
Programmable from 1 to 24 hours
Flow switch
Gas sensor
Hour counter
Yes - accessible by client
Control production of disinfection
g/l
Alarms
Insufficient salt / no flow / pH metering / pH extremely high or low / pH max. metering time / memory error
Display salt concentration
Detects gr salt / l (precision ± 10%)
Production control by pool cover
Programmable 0-100% production of disinfection depending on pool cover open or closed
Production control by ext. signal
Programmable 0-100% production of disinfection depending on external signal (2nd analog. inlet)
Communication
MODBUS / WIFI
Control main outputs
Filtration time / light / temperature
Control additional outputs
4 relays for the control of 4 additional machines for the pool
Life time
guaranteed
Self-cleaning
TOTAL
POOL
CONTROL
TOTAL
POOL
CONTROL
SELF
CLEAN
Programmable
polarity change
Transparent
PVC holder
Security
sensor
SAFETY
SENSOR
Cells for all
pool sizes
250
gr/h
8000 H
Filtration
pump control
Complete
pool control
TOTAL
POOL
CONTROL
TOTAL
POOL
CONTROL
TOTAL
POOL
CONTROL
Light control
Control of 4
additional
machines
Temperature
control
°C
PH-
management
pH
REDOX-
management
rH
Free chlorine
management
CI
2
+4