background image

6

  

/  Salt electrolysis Hidrolife

8.

      

Automatic controls

9.

      

Dimensions

Description

pH

Redox

Free chlorine

Conductivity

Temperature

Reference

Bg

Eg

H

I

T

type of probe

Glass

Glass

Amperometric (Au-Cu)

Glass

Thermometer

Measuring range

0-14 pH

0-1000 mV

0-10 ppm

0-20,000 MS

0-100°C

Measuring precision

0,1 pH

1-3 mV

0,10 ppm

10 MS / 100 MS

1°C

Material

Ag/Cl

Gold

Copper / gold

Stainless steel

Probe holder

ABS 50/63mm

Supplementary equipment

Includes 2 m of flexible tube/valve

Cable

2 m

Plug

BNC with protection

BNC with protection

Connectors

Connectors

Connectors

Summary of Contents for HIDROLIFE

Page 1: ...11 02 2020 REVIZE 11 02 2020 EN Salt electrolysis HIDROLIFE from 3g salt l Portable color display TFT Upgrade possible Worldwide remote control Self clean WIFI and MODBUS Sea water INSTALLATION AND USER GUIDE ...

Page 2: ...eatment system and a controller for swimming pools Water treatment The salt water electrolysis produces chlorine from a base of salt water of low salinity The electrolysis cell attains a production of sodium hypochlorite liquid chlorine from 3g salt per liter The chlorine combats and eliminates bacteria virus pathogenic agents and oxidizes organic matter present in the water The used sodium hypoch...

Page 3: ...ol water Let the circulation pump run during the first 24 hours The system may operate while the salt is dissolving and will operate without problems with salt concentrations from 2 5 g l to 50 g l In pools with strong insolation it s necessary to add 40 gr m3 of stabiliser isocyanuric acid General maintenance 1 The pool must be vacuumed as usual and the skimmers emptied whenever necessary 2 FILTE...

Page 4: ...cell is guaranteed for 5 000 hours approx 2 3 years of summer usage Free chlorine levels don t reach 0 8 ppm Increase filtration interval Increase electrolysis level Check levels of sodium bromide or common salt in the pool 6 gr NaCl l Check level of isocyanuric acid in pool 30 50 ppm only if using common salt Check if reactive agents in test kit are expired Check if the temperature or amount of u...

Page 5: ...m 1 to 24 hours Flow switch Gas sensor Hour counter Yes accessible by client Control production of disinfection g l Alarms Insufficient salt no flow pH metering pH extremely high or low pH max metering time memory error Display salt concentration Detects gr salt l precision 10 Production control by pool cover Programmable 0 100 production of disinfection depending on pool cover open or closed Prod...

Page 6: ...erometric Au Cu Glass Thermometer Measuring range 0 14 pH 0 1000 mV 0 10 ppm 0 20 000 MS 0 100 C Measuring precision 0 1 pH 1 3 mV 0 10 ppm 10 MS 100 MS 1 C Material Ag Cl Gold Copper gold Stainless steel Probe holder ABS 50 63mm Supplementary equipment Includes 2 m of flexible tube valve Cable 2 m Plug BNC with protection BNC with protection Connectors Connectors Connectors ...

Page 7: ...Salt electrolysis Hidrolife 7 Notes ...

Page 8: ...Thank you for using ALBIXON products ALBIXON export albixon com www ALBIXON com Note that the photos used in the manual are illustrative only Printing and typesetting errors reserved ...