ALBIN PUMP AD120 Instruction Manual Download Page 33

33

AD

since 1928

AD

since 1928

Shaft Kit 15.30

Muffler Kit Standard

Studbolt Kit 15-60

Shaft Kit 60

Muffler Kit External

Studbolt Kit 120

Shaft Kit 120

Muffler Kit External with Indicator

K110-001

Pos Description

Qty

31 CEG lockring Outlet

1

28 Muffler Standard

1

K110-002

Pos Description

Qty

31 CEG lockring Outlet

1

28 Insert Outlet

1

n/a Muffler Extended

1

K110-003

Pos Description

Qty

31 CEG lockring Outlet

1

28 Insert Outlet

1

n/a Muffler Extended w indicator

1

Pumphousing AL kit 15

Pumphousing AX kit 15

Pumphousing PP kit 15

Pumphousing PX kit 15

Footplate Kit AL 15-60

Pumphousing AL kit 30

Pumphousing AX kit 30

Pumphousing PP kit 30

Pumphousing PX kit 30

Footplate Kit AL 120

Pumphousing AL kit 60

Pumphousing AX kit 60

Pumphousing PP kit 60

Pumphousing PX kit 60

Footplate Kit PP 15-60

Pumphousing AL kit 120

Pumphousing AX kit 120

Pumphousing PP kit 120

Pumphousing PX kit 120

Footplate Kit PP 120

K106-001

Pos Description

Qty

24 Foot plate

1

26 Rubber foot

4

25 Screw

4

K106-002

Pos Description

Qty

24 Foot plate

1

26 Rubber foot

4

25 Screw

4

K106-010

Pos Description

Qty

24 Foot plate

1

26 Rubber foot

4

25 Screw

4

K109-004

Pos Description

Qty

1

Pumphousing AL 120

1

K109-103

Pos Description

Qty

1

Pumphousing AX 120

1

K109-203

Pos Description

Qty

1

Pumphousing PP 

120

1

K109-303

Pos Description

Qty

1

Pumphousing PX 120

1

K109-001

Pos Description

Qty

1

Pump housing AL 15

1

K109-100

Pos Description

Qty

1

Pumphousing AX 15

1

K109-200

Pos Description

Qty

1

Pumphousing PP 15

1

K109-300

Pos Description

Qty

1

Pumphousing PX 15

1

K109-002

Pos Description

Qty

1

Pumphousing AL 30

1

K109-101

Pos Description

Qty

1

Pumphousing AX 30

1

K109-201

Pos Description

Qty

1

Pumphousing PP 30

1

K109-301

Pos Description

Qty

1

Pumphousing PX 30

1

K109-003

Pos Description

Qty

1

Pumphousing AL 60

1

K109-102

Pos Description

Qty

1

Pumphousing AX 60

1

K109-202

Pos Description

Qty

1

Pumphousing PP 60

1

K109-302

Pos Description

Qty

1

Pumphousing PX 60

1

K106-011

Pos Description

Qty

24 Foot plate

1

26 Rubber foot

4

25 Screw

4

K107-001

Pos Description

Qty

14 Shaft Bushing 15.30

1

15 Shaft 15.30

1

16 Shaft Spring 15.30

1

K108-001

Pos Description

Qty

2

Stud Bolt

4

3

Cap Nuts

8

K108-002

Pos Description

Qty

2

Stud Bolt

4

3

Cap Nuts

8

K107-002

Pos Description

Qty

14 Shaft Bushing 60

1

15 Shaft 60

1

16 Shaft Spring 60

1

K107-003

Pos Description

Qty

14 Shaft Bushing 15.30

1

15 Shaft 120

1

16 Shaft Spring 120

1

(Drawing see section 7.1)

AD Instruction Manual-2011EE-GB.indd   33

25/07/11   09:46

Summary of Contents for AD120

Page 1: ...since 1928 ALBIN PUMP AD AIR OPERATED FLOATING DIAPHRAGM PUMPS INSTRUCTION MANUAL AD Instruction Manual 2011EE GB indd 1 25 07 11 09 45...

Page 2: ...ity with COUNCIL DIRECTIVE on the approximation of the laws of the Member States relating to Machinery 98 37 EG Declaration of incorporation Directive 98 37 EG Annex IIB AD Air Operated Diaphragm Pump...

Page 3: ...d pump installation 4 3 Venting exhaust air 4 4 Before starting the pump 4 5 How to start operate and stop the pump 4 6 Routine maintenance 5 DIRECTIONS FOR DISASSEMBLY AND REASSEMBLY 5 1 Disassembly...

Page 4: ...missing parts a report should be drawn up and presented to the carrier instantly Notify your ALBIN PUMP distributor All pumps have the type specification Type printed on the name plate which is locat...

Page 5: ...iaphragms PTFE can operate continuously between 30 C and 85 C Pump housing PP polypropylene can be used in the interval 0 C and 85 C Aluminium can be used in the same interval as the diaphragms Inside...

Page 6: ...thout damaging the environment or nearby equipment Always install a separate shut off valve for the air supply easily accessible for manoeuvring Pressure variations may cause vibrations in the piping...

Page 7: ...how the check valves are opening and closing In the AD pump the diaphragms are not fixed to the shaft Thanks to this Flexible Diaphragm Suspension FDS invention and the spring at the shaft end the dia...

Page 8: ...T TEFLON PTFE with EPDM carrier 1 6 STANDART PARTS 17 7 5 1 14 15 13 9 11 12 4 8 10 3 2 16 2 18 1 Pump housing 2 Lid 3 Diaphragm 4 Air motor 5 Shaft 6 Shaft spring option 7 Shaft bushing 8 Insert Inl...

Page 9: ...16 1 4436 Spring Stainless steel 316 1 4401 Check valve retainer 30 60 PPS Tedur 40 glass Check valve retainer 120 Stainless steel 316 1 4436 Check valve in and out PEEK O ring Teflon PTFE Screw Stain...

Page 10: ...nless steel 304 1 4301 2332 Air gaskets NBR nitrile Muffler HDPE polyethylene Air O rings NBR nitrile Externals Material AISI DIN SS Foot plate Stainless steel 304 1 4301 2333 Rubber foot NBR nitrile...

Page 11: ...water at 7 bar air pressure and fully open inlet and discharge ports The readings were made at a distance of 1 one metre on the same level as the pump Front 79 5 dB A Left 75 5 dB A Right 74 9 dB A Be...

Page 12: ...2 Reduction for suction lift Important To obtain a long diaphragm life and a high efficiency low air consumption always select a pump which has a max capacity which is as least 1 5 times higher than t...

Page 13: ...flow 30 l min along the horizontal axis Go vertical to the intersection with the required air pressure 3 5 bar and read the air consumption to the left In the example 180 l min Fluid flow lpm 0 50 10...

Page 14: ...CTION FOR SUCTION LIFT AD15 AD120 Viscosity cP 0 10 20 30 40 50 60 70 80 90 100 0 500 1000 1500 2000 2500 3000 3500 Capacity reduction Suction lift m 0 10 20 30 40 50 60 70 80 90 100 0 2 4 6 8 10 Capa...

Page 15: ...Flow Pressure A 6 bar air pressure 87 psi B 4 bar air pressure 58 psi C 2 bar air pressure 29 psi 0 50 100 150 200 250 300 350 0 5 10 15 20 25 30 35 40 45 A B C Air consumption lpm Fluid flow lpm A 6...

Page 16: ...air pressure 87 psi B 4 bar air pressure 58 psi C 2 bar air pressure 29 psi 0 50 100 150 200 250 300 350 0 5 10 15 20 25 30 35 40 45 A B C Air consumption lpm Fluid flow lpm Flow Air consumption A 6...

Page 17: ...id flow lpm A 6 bar air pressure 87 psi B 4 bar air pressure 58 psi C 2 bar air pressure 29 psi 0 50 100 150 200 250 300 350 400 450 0 10 20 30 40 50 60 70 80 90 A B C Air consumption lpm Fluid flow l...

Page 18: ...Fluid flow lpm A 6 bar air pressure 87 psi B 4 bar air pressure 58 psi C 2 bar air pressure 29 psi 0 1 2 3 4 5 6 7 0 20 40 60 80 100 120 140 A B C Fluid outlet pressure Bar Fluid flow lpm Flow Pressur...

Page 19: ...o optimise a good product flow to the pump Use a reinforced non collapsible hose of at least the same inner diameter as the suction port Always consider the following when designing a system make sure...

Page 20: ...so be at least the same diameter as the pump port By increasing the diameter of the piping the friction losses decrease Before using the pump for the first time all external screws and nuts should be...

Page 21: ...educes the pump noise As shown in the illustration a larger muffler can be fitted to further reduce noise 4 4 BEFORE STARTING THE PUMP Ensure that the suction pipes hoses are free from debris It is ad...

Page 22: ...re is less than the fluid discharge pressure 4 6 ROUTINE MAINTENANCE Ensure that the suction pipes hoses are free from debris It is advised to run the pump with a com patible fluid e g water prior to...

Page 23: ...the AD pump are 2 pieces 13 mm combination spanners 2 different hexagon allen keys 2 5 and 5 mm It is also advised to use a small screwdriver to lift O rings and rubber packings For the reassembly a...

Page 24: ...5 and replace if worn Replace the check valves 6 7 if they are worn or distorted It is recommended always to change the PTFE O rings 8 9 once the retainers have been removed 5 1 3 COVERS AND AIR DIST...

Page 25: ...the inlet insert 5 4 Remove the CEG lockring 7 and remove the muffler 8 5 2 REASSEMBLY 5 2 1 AIR MOTOR AND MANIFOLDS 1 Fit the muffler 8 and the CEG lockring outlet 7 2 Fit the inlet insert 5 and the...

Page 26: ...LVES 1 Push the shaft bushing 5 in place Fit two new PTFE O rings 8 and 9 in the pump housing 10 Fit the inlet check valve 6 on one of the retainers 4 Push the retainer firmly in place so it snap lock...

Page 27: ...ed by the stud bolts so there is no risk they come off place 2 Tighten the cap nuts 4 with 22 Nm 5 2 5 AIR MOTOR 1 Fit the complete air motor 2 with air motor gaskets 3 on top of the pump housing Tigh...

Page 28: ...101 118 147 147 123 1 4 3 8 2 5 3 7 AD30 14 145 2 5 64 5 130 97 6 141 101 118 147 147 123 3 8 3 8 2 5 3 7 AD60 14 164 2 5 74 149 97 6 141 101 118 147 147 141 3 4 3 8 3 6 4 9 AD120 14 210 2 5 97 195 9...

Page 29: ...29 AD since 1928 7 0 EXPLODED VIEWS AND PART LISTS 7 1 PUMP AD Instruction Manual 2011EE GB indd 29 25 07 11 09 46...

Page 30: ...exagon screw all incl in Check valve kit with retainer 12 Checkvalve outlet all incl in Check valve kit and Check valve kit with retainer 13 Opening limiter all incl in Check valve kit and Check valve...

Page 31: ...n Air motor kit and Muffler standard kit 29 CEG lockring inlet all Incl in Air motor kit and Air connection kit 30 Insert Inlet all Incl in Air motor kit and Air connection kit 31 CEG lockring outlet...

Page 32: ...motor Gasket External 2 K102 101 Pos Description Qty 7 Checkvalve Inlet 60 2 12 Checkvalve Outlet 60 1 9 O ring Teflon 18 2 8 O ring Teflon 19 2 13 Opening limiter 60 1 14 Shaft Bushing 60 1 6 Checkva...

Page 33: ...tion Qty 1 Pumphousing AL 120 1 K109 103 Pos Description Qty 1 Pumphousing AX 120 1 K109 203 Pos Description Qty 1 Pumphousing PP 120 1 K109 303 Pos Description Qty 1 Pumphousing PX 120 1 K109 001 Pos...

Page 34: ...the seats Replace the shaft bushing pos 14 if it is worn Erratic pump action heavy pulsation Check the diaphragms pos 5 Check that the air motor pivot pos 31 moves freely and that the rubber seals pos...

Page 35: ...AD since 1928 AD Instruction Manual 2011EE GB indd 35 25 07 11 09 46...

Page 36: ...please visit www albinpump com ALBIN PUMP reserves the right to incorporate our latest design and material changes without notice or obligation Design features materials of construction and dimensiona...

Reviews: