Problems and Solutions
If the case should arise that your
CargoMaster
, due to unpre-
dictable reasons, does stop working while climbing stairs,
the following could be wrong:
1. The lead batteries are empty.
l
In such case, wait for 20 to 30 seconds.
During that brief time span the lead batteries
can recuperate sufficiently to make at least
descending of the stairs possible because that
takes very little energy.
2. Technical failure
l
Depending on the situation, do as follows:
l
a) If the device rests on its small supporting
wheels on a step, put it down backwards on
the stairs and remove the load.
l
b) If the device rests on its big wheels on a
step, you can use the
CargoMaster
like a regular
trolley.
+
The reason for the
CargoMaster
´s failure can be the burning of a fuse due to overloading.
Should this be the case, the problem is easily solved by simply changing the 30 A fuse.
+
The trip line of the up/down switch is protected by a 2 A fuse. If the 2 A fuse burns, the
switch and the trip line have to be checked.
If the problem is not solved by substituting the fuses, please
contact your local Alber dealer.