High Speed Doors
Operation
Responsibilities of the operator
The Albany Re-Coil-Away door is designed and manufactured under consideration of safety techni-
cal specifications. This meets the highest standard of safety.
However, this safety can only be reached in operational practice if all necessary measures are met.
It is the duty of the operator of such door system to ensure all these measures and check it‟s status.
Please read the operation manual carefully and keep it in a safe place.
The operator of the door is held to ensure especially that:
Installation, first operation, inspection, servicing, repair work and dismantling are only done by
personnel that have been trained by the manufacturer.
Only to be operated by personnel that have been sufficiently assigned and authorized to operate
this door system.
The door is only used according to the determined application (see above).
The door must be only operated in a functional perfect state and especially the safety features
must be checked for function in regular intervals.
The operation manual should be kept at the site of the fitted door system in readable condition.
All safety and warning labels should not be removed from the machine and should also be kept
readable.
Do not drive through the door opening unless door is completely open.
In power loss condition the electrical drive for the door curtain can be unlocked using the disen-
gagement chains and then the curtain hand chained upwards. When the disengage lever has
been engaged the control system has been disable.
During operation of the door do not stick your hands in the side frames. Keep hands and feet
clear of the door at all times. Stay clear of the door while it is operating.
Human traffic should be avoided within the working area of the door. Existing side doors for hu-
man traffic should be used instead.
Do not run through the door opening. Go upright and with normal pace.
Keep the working vicinity and the opening of the door in clear of obstructions. Maintain a clear
door opening at all times. Obstructions may cause accidents.
Do not climb up the door
For all kind of work on the door the main switch (main disconnect) must be set to the OFF posi-
tion and locked out to prevent power from being reset.
When damage occurs to the door (mechanically or electrically) turn off operational power imme-
diately. This is especially true if you have damage of the curtain or drive system.
USE EXTREME CAUTION
when it is necessary to service the control panel or the auxiliary con-
trol box while it is energized. The door must only be operated with the correct voltage and fre-
quency.
Use only the auxiliaries and devices authorized by the manufacturer of the door.
The
STOP Button on the front of the panel is a momentary stop ONLY with the ACS-50 and Ul-
traSmart panels. The door will only stop for that cycle;
motion detectors, floor loops, or any
activating device can activate the door!
To ensure that the door keeps from being activated,
use the rotary disconnect on the front of the panel.
DO NOT EVER USE PETROLUM BASED PRODUCTS ON THE CURTAIN, IF DONE THIS
VOIDS ALL WARRANTY ON THE CURTAIN MATERIAL.
Pay attention to the general safety advises mentioned under the core point SAFETY but also the
special safety advises mentioned in the other chapters of the operation manual.
Summary of Contents for PosiDrive M&I
Page 10: ...9 Manual 001449 Version 4 2 Activation Repair Replacement ...
Page 11: ...Rev 4 9 2010 Manual 001449 10 High Speed Doors Operation ...
Page 12: ...11 Manual 001449 Version 4 2 ...
Page 13: ...Rev 4 9 2010 Manual 001449 12 High Speed Doors Operation ...
Page 17: ...Rev 4 9 2010 Manual 001449 16 High Speed Doors Operation ...
Page 20: ...19 Manual 001449 Version 4 2 M I Re Coil Away Architectural Over 12 x 12 Balanced ...
Page 22: ...21 Manual 001449 Version 4 2 M I Re Coil Away Architectural Over 12 x 12 Unbalanced ...
Page 24: ...23 Manual 001449 Version 4 2 M I Re Coil Away XL Architectural Over 24 x 27 ...
Page 28: ...27 Manual 001449 Version 4 2 ...
Page 29: ...Rev 4 9 2010 Manual 001449 28 High Speed Doors Operation ...