The lines indicated as GPIO n the silkscreening are assigned as follows:
GPIO5: Error input for the reserve channel.
GPIO4: Error input for the main channel.
GPIO3: Alarm output for the reserve channel.
GPIO2: Alarm output for the main channel.
GPIO1: Indicates selection of:
0V main channel.
+5V reserve channel.
GND: Ground for the module.
During normal operating conditions the alarm outputs GPIO2 and GPIO3 are set to
logic low (transistor on) in order to signal an alarm condition and a no-alarm
condition via a logic high (open collector). This signaling polarity can be inverted using
the control software.
16
Summary of Contents for ASW3000C01
Page 2: ...ASW3000C01 ...
Page 8: ...Albalá Ingenieros Manual ASW3000C01 1 3 Block diagram 8 ...
Page 10: ...Albalá Ingenieros Manual ASW3000C01 ASW3000C01 10 ...
Page 28: ...Albalá Ingenieros Manual ASW3000C01 ASW3000C01 28 ...
Page 30: ...Albalá Ingenieros Manual ASW3000C01 ASW3000C01 30 ...
Page 32: ...Albalá Ingenieros Manual ASW3000C01 ASW3000C01 32 ...