AX1240S-AP-0202C_R2X
35
3. Private MIBs
3.11 ax1250sDevice group (system switch chassis information MIB)
[AX1250S]
3.11.1 ax1250sChassis group implementation specifications (chassis
information) [Change]
The
ax1250sTemperatureStatusNumber
implementation specifications of the
ax1250sChassis
group have
been corrected as follows:
Before the change:
Table 3-27 ax1250sChassis group implementation specifications (chassis information)
# Object
identifier Syntax Access
Implementation
specifications Implemented
Y/N
23 ax1250sTemperatureStatusNumber
{ax1250sChassisEntry 20}
INTEGER R/O Maximum number of temperature
monitoring points in this chassis
For AX1250S series Switches: Fixed value
of 3.
Y
After the change:
Table 3-27 ax1250sChassis group implementation specifications (chassis information)
# Object
identifier Syntax Access
Implementation
specifications Implemented
Y/N
23 ax1250sTemperatureStatusNumber
{ax1250sChassisEntry 20}
INTEGER R/O Maximum number of temperature
monitoring points in this chassis
For AX1250S series Switches: Fixed value
of 1.
Y
3.11.2 ax1250sChassis group implementation specifications
(temperature information) [Change]
The
ax1250sTemperatureState
implementation specifications of the
ax1250sChassis
group have been
corrected as follows:
Before the change:
Table 3-28 ax1250sChassis group implementation specifications (temperature information)
# Object
identifier Syntax Access
Implementation
specifications Implemented
Y/N
7 ax1250sTemperatureState
{ax1250sTemperatureStatusEntry 5}
INTEGER R/O Current temperature state of this
monitoring point:
Normal (
1
)
Warning (
3
)
Y
After the change:
Table 3-28 ax1250sChassis group implementation specifications (temperature information)
# Object
identifier Syntax Access
Implementation
specifications Implemented
Y/N
7 ax1250sTemperatureState
{ax1250sTemperatureStatusEntry 5}
INTEGER R/O Current temperature state of this
monitoring point:
Normal (
1
)
Caution (
2
)
Y