Tolerance
Auto Clear
Angle Threshold
T+A Threshold
First Peak
Direction
S e t u p S e l e c t i o n s
The Tolerance parameters control the Go and No-Go signal response (see Go / No Go Signal section). The user sets
a lower and upper torque thresholds to get a visual and audible warning signals when these limits are reached or
breached during operation. This function is primarily used for safety and quality control.
Tolerance
Tolerance Setting
Low: _0.000 lbf.in
High: 84.950 lbf.in
Main
1. Press the
"Menu"
Button.
2. Use the
Scroll Down
key and select Setup by highlighting and pressing
Enter
.
3. Use the
Scroll Up or Down
key to toggle through the Setup options.
4. Press
Enter
key to select a setup setting for
Tolerance
.
Filter
Units
Mode
Setup
Selecting Tolerance
1. Press the
Right
or
Left
key to toggle between High and Low Tolerance..
2. Use the
Scroll Up or Down
key to change the tolerance settings .
3. Press
Enter
key once setting is complete.
4. Press
Main
button to return to main display screen.
This function controls the method of clearing the display of torque readings.
Auto Clear
When Auto Clear is selected, the torque values, during operation, will automatically be cleared from the display.
The user can set the time threshold to control how long the values should be displayed before clearing.
Manual Clear
When Manual Clear is selected, the torque values during operation will indefinitely be display until the user presses
the Clear key.
Clear
Page 8