10 

You can program the PL6100 to perform certain func-
tions when various events occur.  For a description of all 
features, see the DL-Windows User's Guide, OI237 or 
the Wireless Network Setup & DL-Windows Configura-
tion Instructions, OI352; the most common are listed be-
low. 
 

Lock ID 

Door Number must be between 1– 2000.  If the lock is a 
new lock without a designated LockID, the ID number 
specified in this field will be assigned to the pro-
grammed lock.   
 

Pass Time In Seconds 

The duration in seconds that the PL6100 will remain 
unlocked after a valid proximity card has been 
presented (valid entries are 3, 10 & 15 seconds). 
 

Entry Delay in Seconds 

Delays door entry after valid proximity card has been 
presented.   
 

Lockout # of Attempts 1-9 (DISABLED) 

With other lock models that have keypad buttons, this 
feature is defined as the maximum number of invalid 
entry attempts the lock will allow before it goes into 
"lockout mode" (where it will refuse to recognize ANY 
entry attempts).  The lock will shut down for the period 
programmed in the 

Lockout Time in Seconds 

field 

(see below).  Valid Attempt entries are 1-9.  THIS FEA-
TURE DOES 

NOT 

APPLY TO PROXIMITY CARD EN-

TRIES AND THEREFORE IS DISABLED FOR ALL 
PL6100 LOCKS. 

DL-Windows Programmable Functions 

"Programmable Features" Screen  -  

Options 

tab 

 

Lockout Time in Seconds (Disabled) 

With other lock models that have keypad buttons, this 
feature is defined as the duration of time the lock 
refuses to recognize ANY proximity card presentations 
after the maximum number of invalid entry attempts has 
been reached (valid entries are 1-60 seconds).  THIS 
FEATURE DOES 

NOT 

APPLY TO PROXIMITY CARD 

ENTRIES AND THEREFORE IS DISABLED FOR ALL 
PL6100 LOCKS. 
 

Lock Responds to Emergency Commands 

See the Wireless Network Setup & DL-Windows Con-
figuration Instructions, OI352. 
 

Users are disabled during Lockdown 

See the Wireless Network Setup & DL-Windows Con-
figuration Instructions, OI352. 
 

Group 2 Toggles Passage Mode 

A Group 2 User will toggle passage mode (lock is 
unlocked).  

Caution!  The consequences of acciden-

tally selecting this option can cause a security 
breach!  

 

 

Group 2 Enables and 3 Disables Passage Mode 

A Group 2 User will put the PL6100 into passage mode 
(lock is unlocked).  A Group 3 User will take the PL6100 
out of passage.  

Caution!  The consequences of acci-

dentally selecting this option can cause a security 
breach!   

 

One Time Only for Group 3 Users 

If checked, allows Group 3 Users to unlock the PL6100 
one time only, then their proximity card is disabled.   
 

Disable Sounder 

Disable the Sounder to allow for silent operation.   
 

Enable Entry Sounder 

Check to enable sounder to activate upon each Access 
Granted or Remote Input activation. 
 

Daylight Saving Time 

The lock will adjust for Daylight Saving Time.  See the 
DL-Windows User's Guide, OI237. 

Summary of Contents for Wireless Trilogy Networx PL6100

Page 1: ...Access Control System with ProxCard Access 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 Note Technical Service is for locksmiths and alarm professionals only Publicly traded on NASDAQ Symbol NSSC PL6100 AL PRE PROXCARD READER ENROLLER PROXKEY KEYFOB HID HID HID CORPORATION PROXCARD ...

Page 2: ... compatible ProxCard reader In addition data can be retrieved from the lock to your PC with DL Windows soft ware Its real time clock calendar automatically adjusts for Daylight Saving Time and allows for automated programming of events PL6100 WIRELESS LOCK PL6100 Wireless PL Series Lock Features 3 Supported Products 4 Lock Design Overview 5 Terminology Used in this Manual 6 7 Wiring 8 First Time P...

Page 3: ...isable Groups see page 7 for definition of Group Real time clock and calendar User Access Methods ProxCard and ProxKey Keyfob Batch Enroll Quickly and easily enroll multiple ProxCards and ProxKey keyfobs without the use of a PC Note ProxCards and ProxKey Keyfobs both function identically User Features 5000 Users Service Card One Time Only access see page 7 for User 297 definition Guard Tour see pa...

Page 4: ...as a LAN or corporate Intranet A Windows PC connected to this network can control and program all PL6100 locks by the use of the DL Window software see OI237 and OI352 With access rights to the software one computer or several can control the software and consequently can control the devices in the system Several Gateway device models are available Wireless Wired AL IM80211 Hardwired Wireless Gate...

Page 5: ... needing to be in hand One additional advantage is that proximity cards and fobs cannot be duplicated unlike ordinary metal keys Preparing to Program your Lock As the PL6100 does not feature keypad buttons on its housing programming your PL6100 for example adding or deleting proximity cards is allowed only using a PC that is running the computer software application DL Windows The PC must be conne...

Page 6: ...s to suit the needs of your various installations For exam ple you can program the lock to allow Group 1 Users access ONLY during specific business hours unlock at 9AM lock at noon for lunch unlock at 1PM and lock again at 5PM every weekday In addition DL Windows makes Schedule creation much easier In DL Windows use the Schedule TimeZone screen to first create an individual block of time called a ...

Page 7: ...e proximity card assigned to User Number 297 pos sesses the unique ability to enable the proximity card assigned to User Number 300 When proximity card 297 is presented to the lock proximity card 300 is en abled for one time use allowing passage for one time only Once used User 300 s proximity card becomes disabled For example you wish to allow one time access to a temporary worker Simply present ...

Page 8: ...ower Red Black wires External 7 5 VDC Power Source must be used for operation without batteries Remote Input White White wires Wire a normally open contact to wires white and white Momentarily close to allow PL6100 lock to unlock NOTE Remote Input is enabled from the factory Relay COM Orange N O Green N C Yellow Erase Memory Leads Yellow Yellow wires When shunted during power up the Lock Program m...

Page 9: ... re applying power to a lock already in use you wish to retain the Lock Program such as when moving an existing lock to a new door The lock must be dismantled and powered down for an extended period 1 Disconnect battery pack connector 2 With battery power disconnected short the two white wires Remote Input wires together for 10 seconds to ensure discharge of all capacitors 3 Re connect battery pac...

Page 10: ...kout Time in Seconds Disabled With other lock models that have keypad buttons this feature is defined as the duration of time the lock refuses to recognize ANY proximity card presentations after the maximum number of invalid entry attempts has been reached valid entries are 1 60 seconds THIS FEATURE DOES NOT APPLY TO PROXIMITY CARD ENTRIES AND THEREFORE IS DISABLED FOR ALL PL6100 LOCKS Lock Respon...

Page 11: ... been detected Authorized Entry Activates relay anytime a User presents a valid proximity card and is granted access Scheduled Group 1 Activated Activates relay if the PL6100 has been programmed for Scheduled Relay Activation Group 1 Initiated and a member of Group 1 has presented their proximity card within the required window Locked by Schedule Activates relay if the PL6100 has been locked by a ...

Page 12: ...y card to be pre sented Remote Disables Lock Regardless of the current state of the lock that state will remain unchanged and lock will be disabled for the du ration of Remote Input switch closure Important If this feature is enabled power to the lock MUST be provided from an external power supply Forced Lock Follows Remote When Remote Input switch is closed regardless of the current state of the ...

Page 13: ...13 User Card Record Sheet NAME OF DOOR DEPARTMENT EMBOSSED NUMBER ON CARD USER NAME LAST FIRST DATE ACTIVATED COMMENTS Page ______ ...

Page 14: ...ough DL Windows GROUP 1 PUTS UNIT IN PASSAGE A prox imity card previously assigned to Group 1 pre sented to the lock during a pre defined schedule unlocks the lock Programmed only through DL Windows ONE TIME ONLY FOR GROUP 3 USERS If selected in DL Windows allows Group 3 prox imity cards to unlock the door one time only thereafter their proximity card becomes dis abled See OI237 GUARD TOUR Associa...

Page 15: ...15 NOTES ...

Page 16: ...or au thorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK s original selling price of the prod uct for any loss or damage whether direct indirect incidental consequential or otherwise arising out of any failure of the pro...

Reviews: