10
You can program the PL6100 to perform certain func-
tions when various events occur. For a description of all
features, see the DL-Windows User's Guide, OI237 or
the Wireless Network Setup & DL-Windows Configura-
tion Instructions, OI352; the most common are listed be-
low.
Lock ID
Door Number must be between 1– 2000. If the lock is a
new lock without a designated LockID, the ID number
specified in this field will be assigned to the pro-
grammed lock.
Pass Time In Seconds
The duration in seconds that the PL6100 will remain
unlocked after a valid proximity card has been
presented (valid entries are 3, 10 & 15 seconds).
Entry Delay in Seconds
Delays door entry after valid proximity card has been
presented.
Lockout # of Attempts 1-9 (DISABLED)
With other lock models that have keypad buttons, this
feature is defined as the maximum number of invalid
entry attempts the lock will allow before it goes into
"lockout mode" (where it will refuse to recognize ANY
entry attempts). The lock will shut down for the period
programmed in the
Lockout Time in Seconds
field
(see below). Valid Attempt entries are 1-9. THIS FEA-
TURE DOES
NOT
APPLY TO PROXIMITY CARD EN-
TRIES AND THEREFORE IS DISABLED FOR ALL
PL6100 LOCKS.
DL-Windows Programmable Functions
"Programmable Features" Screen -
Options
tab
Lockout Time in Seconds (Disabled)
With other lock models that have keypad buttons, this
feature is defined as the duration of time the lock
refuses to recognize ANY proximity card presentations
after the maximum number of invalid entry attempts has
been reached (valid entries are 1-60 seconds). THIS
FEATURE DOES
NOT
APPLY TO PROXIMITY CARD
ENTRIES AND THEREFORE IS DISABLED FOR ALL
PL6100 LOCKS.
Lock Responds to Emergency Commands
See the Wireless Network Setup & DL-Windows Con-
figuration Instructions, OI352.
Users are disabled during Lockdown
See the Wireless Network Setup & DL-Windows Con-
figuration Instructions, OI352.
Group 2 Toggles Passage Mode
A Group 2 User will toggle passage mode (lock is
unlocked).
Caution! The consequences of acciden-
tally selecting this option can cause a security
breach!
Group 2 Enables and 3 Disables Passage Mode
A Group 2 User will put the PL6100 into passage mode
(lock is unlocked). A Group 3 User will take the PL6100
out of passage.
Caution! The consequences of acci-
dentally selecting this option can cause a security
breach!
One Time Only for Group 3 Users
If checked, allows Group 3 Users to unlock the PL6100
one time only, then their proximity card is disabled.
Disable Sounder
Disable the Sounder to allow for silent operation.
Enable Entry Sounder
Check to enable sounder to activate upon each Access
Granted or Remote Input activation.
Daylight Saving Time
The lock will adjust for Daylight Saving Time. See the
DL-Windows User's Guide, OI237.
Summary of Contents for Wireless Trilogy Networx PL6100
Page 15: ...15 NOTES ...