![Alarm Lock Trilogy DL2800 Programming Instructions Manual Download Page 22](http://html.mh-extra.com/html/alarm-lock/trilogy-dl2800/trilogy-dl2800_programming-instructions-manual_2888673022.webp)
22
60. Number of Attempts Before Lockout
61. Set the Attempts Lockout Time
•
Number of attempts before lockout must be 1-9 attempts.
•
The number of attempts is reduced by half every time the keypad is locked out without a
successful code entry (default is 6 attempts).
•
The attempt count is reset each time a valid code is entered.
•
Lockout Time must be 1-60 seconds. This functions defines how long the keypad is
locked out after a series of unsuccessful attempts (default is 15 seconds).
4
4
LOCKOUT
; 6 4 :
64. Disable Remote Input
•
Wire a Normally Open Contact to Terminals 3 & 4. Momentarily close to allow person to
pass through door.
•
Enter the functions below to Disable/Enable the Remote Input.
NOTE:
The Remote Input is enabled as part of the default program.
Remote Input Disable/Enable
; 6 5 :
65. Enable Remote Input
66. Reserved
2
REMOTE INPUT
; 6 0 ;
[ _ ]
:
(Number of Attempts)
; 6 1 ;
[ _ _ ]
:
(Lockout Time)
62-63. Reserved
59. Reserved
AL-DTM
Programming Functions (cont'd)
Summary of Contents for Trilogy DL2800