background image

Data Transfer Module 

(

AL-DTM

An 

AL-DTM 

is used to transfer Lock Programs (and other data) between DL-Windows and locks.  

When computers cannot be transported or when electrical power is not available, the hand-held 

AL-

DTM

 device acts as a go-between--it allows the transfer of lock data from the computer (through the 

AL-DTM

) and to the lock, or in reverse (from the lock through the 

AL-DTM

 back to the computer).   

Infrared Printer (AL-IR1) 

An 

AL-IR1

 printer is used to print Audit Trails and User Code lists without the need for a PC.  

Its infrared reader means no cable connection to the lock is needed. 

Double-ended Mini Banana Plug Connector

 

After you create the program in DL-Windows and transfer the program from your computer to an 

AL-DTM

, transfer the program from the 

AL-DTM 

to the lock(s) via a double-ended mini banana 

plug. 

AL-PCI Cable 

An ALARM LOCK 

AL-PCI 

cable is required to communicate between your computer’s RS-232 

serial communications port (COM 1-4) and the 

AL-DTM 

or lock.  One end of the 

AL-PCI

 cable is 

designed to be used on a 9-pin serial Com Port.  If your computer has a 25-pin Com Port only, a 
25-pin to 9-pin adapter must be used.  The other end of the 

AL-PCI 

cable features a 2-pin ba-

nana plug connector which is polarity sensitive--the TAB (marked “GND”) side must be plugged 
into the lock’s 

black 

(left) terminal. 

Supported Products 

USB to RS-232 Cable 

If your computer does not have a serial COM port (DB-9 male) available, you can plug your AL-
PCI2 cable into a special USB to RS-232 cable.  Order part PCI-USB for the USB to RS-232 
cable only, or ALPCI2-U for both the USB to RS-232 cable and an AL-PCI2 cable). 

Summary of Contents for Trilogy DL1300

Page 1: ...Series Stand Alone Access Control Systems OI311 7 06 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 ALARM LOCK 2006 AL DTM DATA...

Page 2: ...r Adams Rite 4710 4730 and 4900 deadlatch locks and 1850 1950 4070 MS1850S and MS1950S series deadbolts for narrow stile aluminum doors Features a real time clock calendar that automatically adjusts f...

Page 3: ...tion 3 Enable Disable Groups see page 17 Four Quick Schedules contains 4 most common schedules see page 25 Real time clock and calendar see page 19 Programmable Timeout Functions see page 17 20 User A...

Page 4: ...your computer to an AL DTM transfer the program from the AL DTM to the lock s via a double ended mini banana plug AL PCI Cable An ALARM LOCK AL PCI cable is required to communicate between your comput...

Page 5: ...d to get your lock to start working To begin programming you must first enter something called Program Mode What is Program Mode With hardware hand tools can be used to make fixes or changes With soft...

Page 6: ...can hold up to 2000 Users in its programming memory and each User possesses a pre defined level of authority a Programming Level as to their ability to use or make changes to the lock What is a Progr...

Page 7: ...entering their own User 297 User Code into the lock keypad When User 300 subsequently enters their User 300 User Code the lock allows access for one time and then the User 300 User Code becomes disabl...

Page 8: ...Users 7 8 and 9 Can only program functions relating to day to day operation Abbreviated as Programming Level 2 Print Only Users Always associated with Users 10 11 Restricted to print audit trails onl...

Page 9: ...ssed during code entry hold any key continuously until the error sound is heard 7 short beeps this will clear the entry Re enter the key sequence again All program sequences are followed by the key 2...

Page 10: ...RIAL PORT COM 1 4 DL1300 LOCK Send to lock Receive from lock Scenario 2 Create the program in DL Windows and transfer the program from your computer to an AL DTM via an AL PCI cable then transfer the...

Page 11: ...not known proceed directly to ALTERNATIVE METHOD below Wait for the green light and press until multiple beeps are heard You are now in Program Mode 2 Press 99 000 3 Listen for 6 beeps The lock will r...

Page 12: ...w that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly below and program various functions Note...

Page 13: ...t the anticipated sequence does not currently open the lock If the lock does not open the anticipated Mas ter Code can be used as the new Master Code if the lock opens the anticipated Master Code alre...

Page 14: ...on 43 Speed Up Clock See page 20 Function 44 Slow Down Clock See page 20 Function 45 46 Passage Mode Enable Disable See page 20 Function 47 Timed Passage Mode See page 20 Programming Functions Overvie...

Page 15: ...on page 5 for more information about Master Codes 3 M USERS Lock Defaults for DL1300 See page 8 Users added will default to a Group association and a Programming Level as follows USER TYPE USER NUMBER...

Page 16: ...rogram Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a...

Page 17: ...main 3 13 Clear All Timeout Functions This Function enabled through keypad only CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will each overri...

Page 18: ...ssociation As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manua...

Page 19: ...s and ends at 2AM on the programmed date Enter 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Defa...

Page 20: ...Code Re Lock using Function 46 Programmed Schedules will override the state of the lock when Functions 45 and 46 are used If it is required that programmed schedules do not override Passage Mode enab...

Page 21: ...r Code is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time...

Page 22: ...ve To abort printing press any key for 3 seconds three short beeps will sound Hold the printer over the lock s infrared sensor as shown in Figure 1 and Figure 2 above For use with DL WINDOWS software...

Page 23: ...he keypad is locked out without a successful code entry default is 6 attempts The attempt count is reset each time a valid code is entered Lockout Time must be 1 60 seconds How long the keypad is lock...

Page 24: ...8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule...

Page 25: ...riday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Note Use Function 49 to disable Scheduled Passage Mode Scheduled Pass...

Page 26: ...d within this window Group 4 members will be enabled Group 4 members will still need to enter their User Codes to enter For additional information see Group 1 Activated Features on page 27 For day ent...

Page 27: ...e if any Group 1 User Code is entered within the programmed window the User Codes in Group 4 will be enabled If a Group 1 User does not enter their User Code during the specified window Functions 92 9...

Page 28: ...the time to close the window 10 00 A M all days of the week Function 92 Open Window Time 8 30 A M Press 9 2 0 0 8 3 0 Function 93 Close Window Time 10 00 A M Press 9 3 0 1 0 0 0 6 Exit Program Mode ho...

Page 29: ...Programming 43 44 Clock Adjust 52 53 54 Pass Time 3 sec 10 sec 15 sec 60 Set Lockout Attempts 61 Set Lockout Time 69 70 Enter Key Enable Disable 0 55 0 0 Seconds 1 9 Attempts 6 1 60 seconds 1 8 Defau...

Page 30: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Page 31: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Page 32: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Page 33: ...nctions can be programmed For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter Time of Day in...

Page 34: ...nctions can be programmed For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter Time of Day in...

Page 35: ...and when the lock is first started or when power is removed and re applied see Wiring and Power Up page 11 the original factory default settings are re loaded and take effect DISABLE Turn off DOOR NUM...

Page 36: ...r authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for...

Reviews: