background image

36 

ALARM LOCK LIMITED WARRANTY

 

ALARM LOCK  SYSTEMS, INC. (ALARM LOCK) warrants its products to be free from manufacturing defects in 
materials and workmanship for 24 months following the date of manufacture. ALARM LOCK will, within said period, at 
its option, repair or replace any product failing to operate correctly without charge to the original purchaser or user. 

This warranty shall not apply to any equipment, or any part thereof, which has been repaired by others, improperly 
installed, improperly used, abused, altered, damaged, subjected to acts of God, or on which any serial numbers have 
been altered, defaced or removed. Seller will not be responsible for any dismantling or reinstallation charges. 

THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION ON 
THE FACE HEREOF. THERE IS NO EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY OR A 
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. ADDITIONALLY, THIS WARRANTY IS IN LIEU OF 
ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF ALARM LOCK. 

Any action for breach of warranty, including but not limited to any implied warranty of merchantability, must be 
brought within the six months following the end of the warranty period. IN NO CASE SHALL ALARM LOCK BE 
LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY 
OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S 
OWN NEGLIGENCE OR FAULT. 

In case of defect, contact the security professional who installed and maintains your security system. In order to 
exercise the warranty, the product must be returned by the security professional, shipping costs prepaid and insured 
to ALARM LOCK. After repair or replacement, ALARM LOCK assumes the cost of returning products under warranty. 
ALARM LOCK shall have no obligation under this warranty, or otherwise, if the product has been repaired by others, 
improperly installed, improperly used, abused, altered, damaged, subjected to accident, nuisance, flood, fire or acts 
of God, or on which any serial numbers have been altered, defaced or removed. ALARM LOCK will not be 
responsible for any dismantling, reassembly or reinstallation charges. 

This warranty contains the entire warranty. It is the sole warranty and any prior agreements or representations, 
whether oral or written, are either merged herein or are expressly canceled. ALARM LOCK neither assumes, nor 
authorizes any other person purporting to act on its behalf to modify, to change, or to assume for it, any other 
warranty or liability concerning its products. 

In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCK's original selling price of the 
product, for any loss or damage, whether direct, indirect, incidental, consequential, or otherwise arising out of any 
failure of the product. Seller's warranty, as hereinabove set forth, shall not be enlarged, diminished or affected by and 
no obligation or liability shall arise or grow out of Seller's rendering of technical advice or service in connection with 
Buyer's order of the goods furnished hereunder. 

ALARM LOCK RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY. 

Warning: Despite frequent testing, and due to, but not limited to, any or all of the following; criminal tampering, 
electrical or communications disruption, it is possible for the system to fail to perform as expected. ALARM LOCK 
does not represent that the product/system may not be compromised or circumvented; or that the product or system 
will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; nor that the product or system 
will in all cases provide adequate warning or protection. A properly installed and maintained alarm may only reduce 
risk of burglary, robbery, fire or otherwise but it is not insurance or a guarantee that these events will not occur. 
CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, 
OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. Therefore, the installer 
should in turn advise the consumer to take any and all precautions for his or her safety including, but not limited to, 
fleeing the premises and allege police or fire department, in order to mitigate the possibilities of harm and/or damage. 

ALARM LOCK is not an insurer of either the property or safety of the user's family or employees, and limits its liability 
for any loss or damage including incidental or consequential damages to ALARM LOCK's original selling price of the 
product regardless of the cause of such loss or damage. 

Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation 
of incidental or consequential damages, or differentiate in their treatment of limitations of liability for ordinary or gross 
negligence, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights 
and you may also have other rights which vary from state to state.

 

Summary of Contents for Trilogy DL1300

Page 1: ...Series Stand Alone Access Control Systems OI311 7 06 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 ALARM LOCK 2006 AL DTM DATA...

Page 2: ...r Adams Rite 4710 4730 and 4900 deadlatch locks and 1850 1950 4070 MS1850S and MS1950S series deadbolts for narrow stile aluminum doors Features a real time clock calendar that automatically adjusts f...

Page 3: ...tion 3 Enable Disable Groups see page 17 Four Quick Schedules contains 4 most common schedules see page 25 Real time clock and calendar see page 19 Programmable Timeout Functions see page 17 20 User A...

Page 4: ...your computer to an AL DTM transfer the program from the AL DTM to the lock s via a double ended mini banana plug AL PCI Cable An ALARM LOCK AL PCI cable is required to communicate between your comput...

Page 5: ...d to get your lock to start working To begin programming you must first enter something called Program Mode What is Program Mode With hardware hand tools can be used to make fixes or changes With soft...

Page 6: ...can hold up to 2000 Users in its programming memory and each User possesses a pre defined level of authority a Programming Level as to their ability to use or make changes to the lock What is a Progr...

Page 7: ...entering their own User 297 User Code into the lock keypad When User 300 subsequently enters their User 300 User Code the lock allows access for one time and then the User 300 User Code becomes disabl...

Page 8: ...Users 7 8 and 9 Can only program functions relating to day to day operation Abbreviated as Programming Level 2 Print Only Users Always associated with Users 10 11 Restricted to print audit trails onl...

Page 9: ...ssed during code entry hold any key continuously until the error sound is heard 7 short beeps this will clear the entry Re enter the key sequence again All program sequences are followed by the key 2...

Page 10: ...RIAL PORT COM 1 4 DL1300 LOCK Send to lock Receive from lock Scenario 2 Create the program in DL Windows and transfer the program from your computer to an AL DTM via an AL PCI cable then transfer the...

Page 11: ...not known proceed directly to ALTERNATIVE METHOD below Wait for the green light and press until multiple beeps are heard You are now in Program Mode 2 Press 99 000 3 Listen for 6 beeps The lock will r...

Page 12: ...w that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly below and program various functions Note...

Page 13: ...t the anticipated sequence does not currently open the lock If the lock does not open the anticipated Mas ter Code can be used as the new Master Code if the lock opens the anticipated Master Code alre...

Page 14: ...on 43 Speed Up Clock See page 20 Function 44 Slow Down Clock See page 20 Function 45 46 Passage Mode Enable Disable See page 20 Function 47 Timed Passage Mode See page 20 Programming Functions Overvie...

Page 15: ...on page 5 for more information about Master Codes 3 M USERS Lock Defaults for DL1300 See page 8 Users added will default to a Group association and a Programming Level as follows USER TYPE USER NUMBER...

Page 16: ...rogram Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a...

Page 17: ...main 3 13 Clear All Timeout Functions This Function enabled through keypad only CLEAR FUNCTIONS Group Enable Disable Enter the functions below to Enable Disable Groups Functions 14 23 will each overri...

Page 18: ...ssociation As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manua...

Page 19: ...s and ends at 2AM on the programmed date Enter 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Defa...

Page 20: ...Code Re Lock using Function 46 Programmed Schedules will override the state of the lock when Functions 45 and 46 are used If it is required that programmed schedules do not override Passage Mode enab...

Page 21: ...r Code is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time...

Page 22: ...ve To abort printing press any key for 3 seconds three short beeps will sound Hold the printer over the lock s infrared sensor as shown in Figure 1 and Figure 2 above For use with DL WINDOWS software...

Page 23: ...he keypad is locked out without a successful code entry default is 6 attempts The attempt count is reset each time a valid code is entered Lockout Time must be 1 60 seconds How long the keypad is lock...

Page 24: ...8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule...

Page 25: ...riday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Note Use Function 49 to disable Scheduled Passage Mode Scheduled Pass...

Page 26: ...d within this window Group 4 members will be enabled Group 4 members will still need to enter their User Codes to enter For additional information see Group 1 Activated Features on page 27 For day ent...

Page 27: ...e if any Group 1 User Code is entered within the programmed window the User Codes in Group 4 will be enabled If a Group 1 User does not enter their User Code during the specified window Functions 92 9...

Page 28: ...the time to close the window 10 00 A M all days of the week Function 92 Open Window Time 8 30 A M Press 9 2 0 0 8 3 0 Function 93 Close Window Time 10 00 A M Press 9 3 0 1 0 0 0 6 Exit Program Mode ho...

Page 29: ...Programming 43 44 Clock Adjust 52 53 54 Pass Time 3 sec 10 sec 15 sec 60 Set Lockout Attempts 61 Set Lockout Time 69 70 Enter Key Enable Disable 0 55 0 0 Seconds 1 9 Attempts 6 1 60 seconds 1 8 Defau...

Page 30: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Page 31: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Page 32: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Page 33: ...nctions can be programmed For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter Time of Day in...

Page 34: ...nctions can be programmed For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter Time of Day in...

Page 35: ...and when the lock is first started or when power is removed and re applied see Wiring and Power Up page 11 the original factory default settings are re loaded and take effect DISABLE Turn off DOOR NUM...

Page 36: ...r authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for...

Reviews: