RELAY OUTPUT OPERATION ANNOUNCER (Function 72)
Enter programming mode by entering Program Code and * *
(1) FUNCTION
Key in Function
(2) FUNCTION MODES FOR OUTPUT ANNOUNCER
Output announcer gives notification Echo Tone on the operation status of the output relay. There are
two notification modes available for the selection. The notification can also be OFF while the
Keystroke Echo Tone OFF mode is selected. See Function 71 (Page 21).
---
No Notification
The output operation notification is OFF but does note affect the normal Keystoke Echo tones.
Note: The green LED will stay illuminated for the entire length of time that the relay is energized.
---
1 Second Long Notification -- (Default)
1 second notification Echo Tone is given when the output relay activates. It is prepared to notify the
person outside the door when the lock is released and the door can be opened. It is good for door
lock that gives no sound when it activates, such as a magnetic lock. Note: The green LED will stay
illuminated for the entire length of time that the relay is energized.
---
2 Short Beeps Notification
2 short Echo Tones. Echo Tones sound when the output relay activates. Note: The green LED will
stay illuminated for the entire length of time that the relay is energized.
(3) VALIDATION
Press
key once . Two-Echo Tones confirms the entry
When finished press * * to exit Programming Mode.
STATUS LED FLASHING ON-OFF DURING STANDBY (Function 73)
Enter Programming Mode by entering Program Coe and * *
(1) FUNCTION
Key in Function
(2) FUNCTION MODES FOR STANDBY FLASHING LIGHT
Some people find the flashing light of the status LED (the amber LED) is unpleasent during standby,
especially at the night time. The standby flashing can be ON-OFF with the setting here.
1
---
Standby Flashing ON -- (Default)
The Status LED gives Standby Flashing all the time. It also gives the light indications showing the
operation status of the system.
0
---
Standby Flashing OFF
The Standby Flashing is OFF but it does not affect the system status indications.
(3) VALIDATION
Press
key once . Two-Echo Tones confirms the entry
When finished press * * to exit Programming Mode.
11
VALIDATION
1
or
(2)
(1)
FUNCTION MODES
VALIDATION
FUNCTION
1
or
0
#
73
(2)
(3)
(1)
72
73
2
22
0
#
(3)
FUNCTION MODES
FUNCTION
72
2
or
Summary of Contents for KP-100A